Concept explainers
The mass flow rate of water in a tube is measured using a beaker to catch water during a timed interval. The nominal mass flow rate is l00 g/s. Assume that mass is measured using a balance with a least count of 1 g and a maximum capacity of 1 kg, and that the timer has a least count of 0.1 s. Estimate the time intervals and uncertainties in measured mass flow rate that would result from using 100, 500, and 1000 mL beakers. Would there be any advantage in using the largest beaker? Assume the tare mass of the empty 1000 mL beaker is 500 g.
Want to see the full answer?
Check out a sample textbook solutionChapter 1 Solutions
Fox and McDonald's Introduction to Fluid Mechanics
Additional Engineering Textbook Solutions
Web Development and Design Foundations with HTML5 (8th Edition)
Thinking Like an Engineer: An Active Learning Approach (4th Edition)
INTERNATIONAL EDITION---Engineering Mechanics: Statics, 14th edition (SI unit)
Degarmo's Materials And Processes In Manufacturing
Thermodynamics: An Engineering Approach
Starting Out with C++ from Control Structures to Objects (9th Edition)
- 1 The following observations are recorded during a test on a four-stroke petro engine, F.C = 25cc of fuel in 10 sec, speed of the engine is 2600 rpm, B.P = 22 kW, Qair 0.00134 m, piston diameter 90 mm, density of the fuel = 0.85gm/cc , compression ratio = 7.5, CV of fuel = 42000KJ/Kg, room temperature = 24 °C %3D = 140mm, stroke length = %3D %3D %3D 2 A six-cylinder 4-stroke cycle petrol engine is to be designed to develop 250 kW of (b.p) at 2200 rpm the stroke / bore ratio is to be 1.3:1. Assuming nm =80% and an indicated mean effective pressure of 9.5 bar, determine the required bore and stroke. If the compression ratio of the engine is to be 7.5 to 1, determine consumption of petrol in kg/h and in kg/bp.hr. Take the ratio of the indicated thermal efficiency of the engine to that of the constant volume air standard cycle as 0.65 and the calorific value of the petrol as; 44770KJ/kg.arrow_forwardDetermine the blade length for a wind turbine that supplies an electrical power output of 1.95 MW and given the following parameters: Wind speed = 51 km/hr The gear, generator and electric efficiencies are 93%, 95% and 91% respectively. The power coefficient of the wind turbine is the maximum possible as given by the Lanchester-Betz limit. Assume the atmospheric air conditions are 1.01325 bar and 27 °Carrow_forwardPlease correct solution toarrow_forward
- A thermometer having a time constant of 0.2 min is placed in a temperature bath, and after the thermometer comes to equilibrium with the bath, the temperature of the bath is increased linearly with time at a rate of l0 C/min. What is the difference between the indicated temperature and the bath temperature (a) 0.1 min, (b) 1.0 min after the change in temperature begins?arrow_forwardExperiment Data Take the following data for the syringe injection pump 2/ Inner diameter of syringe barrel: D = 1.5 cm Inner diameter of the needle shaft of the syringe: d = 0.5 mm The thread pitch of lead screw: pt = 0.75 mm Lead screw rotation velocity (rpm): n Calculations a Liquid injection rate (cm³/hr) Q = pt*n* 60 * π * D²/4 Velocity of liquid in syringe barrel (cm/min) vb = 40/ (60** D²) Velocity of liquid in syringe needle (cm/min) v₁ = 40/ (60*n* d²) b Find the rotation velocity of lead screw n and the velocity of liquid in syringe needle if the required injection dose is 1. 10 cm³ in 3 hours (continuous injection) 2. 20 cm³ in 12 hours (discontinuous injection, 5 cm³ each 3 hour, injection time = 1 min). Discus the recl Solution Calculate the liquid injection rate Q = P₁ xnx60xD² = 0.075xnx60××1.5² = 7.94n- cm³ hr Calculate the velocity of liquid in barrel V₁ == 40 60xπx D² 4x7.94n 60xx1.5² = 0.07ncm hr Calculate the velocity of liquid in needle 40 60xxxd2 4x7.94n 60xπx…arrow_forwardA control valve is used to manipulate a liquid flowrate in the flowrate control loop. Figure 2 shows the flow characteristic of the control valve.Determine the following: i. Type of flow characteristic of the control valve.ii. Flowrate through the valve if the valve travel is 45%. Noted that the flowrate of the liquid is 70 000 lb/h when the valve is fully opened.iii. The maximum flow coefficient of the control valve, if the density of the liquid is half of the density of water and the pressure drop across the valve is 10 psi.arrow_forward
- Calculate the individual uncertainties associated for measuring this velocity from the provide individual values given by the manufacture. Then determine the design stage instrument uncertainty. Which uncertainty (or which couple of uncertainties) is the most significant contributor? You attempt to determine the validity of a mass balance in your lab by repeatedly placing 100 g calibration weight on it. Fifteen readings were obtained with values of 101.2, 100.1, 99.8, 100.5, 101.1, 100, 100, 99.6, 101.5, 100.8, 100.9, 100.3, 99.8, 100.5, and 100.9 Estimate the bias error and the maximum precision error of the measurementsarrow_forward(b) A pitot-static probe is use to determine the flow velocity by measuring the differential pressure. The pitot formula to obtain the flow velocity is, 2(P- P,) V = where, V is the velocity, P is pressure and pis fluid density. i) The pressure difference sensor use in the system is electronic types and the output of the device is measured in voltage. The output of the pressure device is 3.5 V and the linear relationship between the device and the pressure difference is 10 kPa/V. If the measured fluid is water at 20°C, determine the pressure difference inside the system the water velocity. ii) The Pitot-static tube is also commonly use in aircraft. An aircraft flying at 3000 m above sea level when the differential pressure reading clocked 3 kPa. Determine the speed of the aircraft.arrow_forwardNonearrow_forward
- Experiment Data Take the following data for the syringe injection pump 2/ Inner diameter of syringe barrel: D = 1.5 cm Inner diameter of the needle shaft of the syringe: d = 0.5 mm The thread pitch of lead screw: pt = 0.75 mm Lead screw rotation velocity (rpm): n Calculations Liquid injection rate (cm³/hr) Q = pt*n* 60 * * D²/4 Velocity of liquid in syringe barrel (cm/min) v = 4Q/ (60** D²) Velocity of liquid in syringe needle (cm/min) v₁ = 40/ (60* *d²) K Find the rotation velocity of lead screw n and the velocity of liquid in syringe needle if the required injection dose is 1. 10 cm³ in 3 hours (continuous injection) 2. 20 cm³ in 12 hours (discontinuous injection, 5 cm³ each 3 hour, injection time = 1 min). Discus the rece Solution Calculate the liquid injection rate Q = P₁ xnx60x² = 0.075xnx60xx1.5 = 7.94n- cm³ hr Calculate the velocity of liquid in barrel V₁ == 40 60xπx D² 4x7.94n 60xx1.5² = 0.07ncm hr Calculate the velocity of liquid in needle 40 60xπxd² 4x7.94n 60xπx 0.05² hr…arrow_forwardOn a single plot, show curves that show the relationship between the pressure generated by the pump as a function of flow rate of water at 20 °C through the three branches of the piping system shown below (this phrasing means that AP should be on the y axis and flow rate on the x axis; the range of the pressure should be 0 to ~1 MPa). (Branches 1 and 3 are in the same plane; branch 2 is located 5 m above the other two branches) Pump Some important information: A 10 m Branch 2 Branch 1 20 m from point B to pump Branch 3 B 5 m Pipe inner diameter: 0.0254 m Pipe material: copper Typical mass flow rate of interest: 0.5 kg/s Ignore minor losses of tee's at points A and B and any features of branch 3 Consider minor losses of two 90° elbows in branch 2arrow_forwardA water truck drives slowly around a construction site, spraying water to keep dust down. A pump maintains a constant pressure of 100 kPa, gage, and the water is dispersed through 20 spray nozzles, each of diameter 1 cm. If the truck is initially filled with 4000 L of water, and the flow rate is constant, determine how long the truck can drive before a refill is needed. [57.0 s]arrow_forward
- Principles of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage Learning