The single line diagram for a sample power system is as given in Fig.1. Draw a per unit reactance diagram. The ratings of the power system components are as follows: : 20 MVA, 10.5 kV, X" = 0.1 pu : 15 MVA, 6.2 kV, X" = 0.15 pu Transformer T1, T4 (36) : 30 MVA, 66/11 kV, X= 0.2 pu Transformer T2, T; (30) : 20 MVA, 66/6.6 kV, X = 0.15 pu Generator, G1 Generator, G2 Sync. Motor, M1 :15 MVA, 6.6 kV, X" = 0.15 pu Sync. Motor, M2 : 15 MVA, 11 kV, X" = 0.2 pu Consider a base of 100 MVA, 66 kV in the (30+ j100) n transmission line. TI T3 30 +j 100 2 G1 MI 15 +j 50 2 15 +j 50 12 T2 T4 G2 M2

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
The single line diagram for a sample power system is as given in Fig.1. Draw a per unit reactance diagram. The
ratings of the power system components are as follows:
: 20 MVA, 10.5 kV, X" = 0.1 pu
: 15 MVA, 6.2 kV, X" = 0.15 pu
Transformer T1, T4 (36) : 30 MVA, 66/11 kV, X= 0.2 pu
Transformer T2, T; (30) : 20 MVA, 66/6.6 kV, X = 0.15 pu
Generator, G1
Generator, G2
Sync. Motor, M1
:15 MVA, 6.6 kV, X" = 0.15 pu
Sync. Motor, M2
: 15 MVA, 11 kV, X" = 0.2 pu
Consider a base of 100 MVA, 66 kV in the (30+ j100) n transmission line.
TI
T3
30 +j 100 2
G1
MI
15 +j 50 2
15 +j 50 12
T2
T4
G2
M2
Transcribed Image Text:The single line diagram for a sample power system is as given in Fig.1. Draw a per unit reactance diagram. The ratings of the power system components are as follows: : 20 MVA, 10.5 kV, X" = 0.1 pu : 15 MVA, 6.2 kV, X" = 0.15 pu Transformer T1, T4 (36) : 30 MVA, 66/11 kV, X= 0.2 pu Transformer T2, T; (30) : 20 MVA, 66/6.6 kV, X = 0.15 pu Generator, G1 Generator, G2 Sync. Motor, M1 :15 MVA, 6.6 kV, X" = 0.15 pu Sync. Motor, M2 : 15 MVA, 11 kV, X" = 0.2 pu Consider a base of 100 MVA, 66 kV in the (30+ j100) n transmission line. TI T3 30 +j 100 2 G1 MI 15 +j 50 2 15 +j 50 12 T2 T4 G2 M2
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,