Specifications: M20 Bolts in standard holes. Nominal hole diameter = 22mm Effective Hole diameter = nominal hole diameter + 2 mm A325 steel bolt Assume thread in shear plane Fv = 372 MPa Properties of Angle Bar < 125 x 125 x 13 mm A = 3065 mm² x = 36.3 mm y = 36.3 mm Fy = 248 MPa , Fu = 410 MPa  1. Considering shearing in bolts, what is the allowable force P (kN) that the connection can handle if allowable shearing stress in bolts is Fv/2  a. 257.61 b. 390.25 c. 233.73 d. 309.25 2. Considering yielding of angle bar, what is the allowable force P that the connection can handle if allowable yielding stress in gross area of angle bar is Fy/1.67 a. 201.25

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter1: Heat, Temperature, And Pressure
Section: Chapter Questions
Problem 17RQ: Convert 22C to Fahrenheit.
icon
Related questions
Question

In the Bolted Connection shown, find the following by ASD.

Specifications:
M20 Bolts in standard holes.
Nominal hole diameter = 22mm
Effective Hole diameter = nominal hole diameter + 2 mm
A325 steel bolt
Assume thread in shear plane
Fv = 372 MPa
Properties of Angle Bar
< 125 x 125 x 13 mm
A = 3065 mm²
x = 36.3 mm
y = 36.3 mm
Fy = 248 MPa , Fu = 410 MPa 

1. Considering shearing in bolts, what is the allowable force P (kN) that the connection can handle if allowable shearing stress in bolts is Fv/2 
a. 257.61
b. 390.25
c. 233.73
d. 309.25
2. Considering yielding of angle bar, what is the allowable force P that the connection can handle if allowable yielding stress in gross area of angle bar is Fy/1.67
a. 201.25
b. 455.16
c. 403.03
d. 509.25
3. For angle bars used as bolted tension element connected to another element only on one leg, the effective area Ae = UAn. Where: An = Net area, U = Shear lag factor = 1 – x/L, L= center to center longitudinal distance of extremely located fasteners, X= distance from centroid of angle bar to surface of contact of joined elements. What is the shear lag factor of our angular bar? 
a. 0.454
b. 0.9
c. 0.838
d. 0.869
4. Considering RUPTURE of angle bar, what is the allowable force P that the connection can handle if allowable RUPTURE stress in net area of angle bar is Fu/2
a. 463.83 kN
b. 472.94 kN
c. 483. 26 kN
d. 409.19 kN
s0, 75 75
75
75
P
50
Transcribed Image Text:s0, 75 75 75 75 P 50
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Axial Load
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning