QUESTION 5 ✓ A 100 kVA, 7200 -480 V 50 Hz single phase transformer has the following parameters all given in ohms: RLS = 0.00800 RHS = 1.96 RfеHS = 53.2 XLS = 0.01510 XHS=4.55 XMHS=7800 This transformer is operated in step-down mode and delivers 75% of its rated power to a load that has a power factor of 0.93 lagging. a) Draw the equivalent circuit model of the transformer with the equivalent series Z's referred to the high voltage side (3 Marks) b) Find the total Zin of the transformer at the high side (3 Marks) c) Find input Z of the transformer with the load disconnected (3 Marks) d) Find input voltage at 75% of the load required to maintain the rated load voltage (3 Marks) e) Find an exciting current with the load disconnected (3 Marks). 60 Marks

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.5MCQ: For an ideal 2-winding transformer, an impedance Z2 connected across winding 2 (secondary) is...
icon
Related questions
Question
100%
QUESTION 5 ✓
A 100 kVA, 7200 -480 V 50 Hz single phase transformer has the following parameters all given
in ohms:
RLS = 0.00800 RHS = 1.96 RfеHS = 53.2
XLS = 0.01510 XHS=4.55 XMHS=7800
This transformer is operated in step-down mode and delivers 75% of its rated power to a load that
has a power factor of 0.93 lagging.
a) Draw the equivalent circuit model of the transformer with the equivalent series Z's referred to
the high voltage side (3 Marks)
b) Find the total Zin of the transformer at the high side (3 Marks)
c) Find input Z of the transformer with the load disconnected (3 Marks)
d) Find input voltage at 75% of the load required to maintain the rated load voltage (3 Marks)
e) Find an exciting current with the load disconnected (3 Marks).
60 Marks
Transcribed Image Text:QUESTION 5 ✓ A 100 kVA, 7200 -480 V 50 Hz single phase transformer has the following parameters all given in ohms: RLS = 0.00800 RHS = 1.96 RfеHS = 53.2 XLS = 0.01510 XHS=4.55 XMHS=7800 This transformer is operated in step-down mode and delivers 75% of its rated power to a load that has a power factor of 0.93 lagging. a) Draw the equivalent circuit model of the transformer with the equivalent series Z's referred to the high voltage side (3 Marks) b) Find the total Zin of the transformer at the high side (3 Marks) c) Find input Z of the transformer with the load disconnected (3 Marks) d) Find input voltage at 75% of the load required to maintain the rated load voltage (3 Marks) e) Find an exciting current with the load disconnected (3 Marks). 60 Marks
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning