Q1-A 3-phase step down transformer 1200 KVA , 11000/2200 V, 50 Hz .The resistance /phase and leakage reactance/phase of the primary winding are 1.22 and 4.82 and the corresponding values for the secondary winding are 0.012 and 0.06N respectively if the primary winding is connected in delta and secondary in star. calculate: i)The voltage to be applied at normal frequency to the primary to circulate full-load current through it when the secondary is short-circuited ii) The full load copper loss

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Q1-A 3-phase step down transformer 1200 KVA , 11000/2200 V, 50 Hz .The resistance /phase and leakage reactance/phase of the primary winding are 1.2Q and 4.8Q and the corresponding values for the secondary winding are 0.01Q and 0.06Q respectively if the primary winding is connected in delta and secondary in star. calculate: 1)The voltage to be applied at normal frequency to the primary to circulate full-load current through it when the secondary is short-circuited ii) The full load copper loss Q2- A 3-phase 250KVA, 11000/416 transformer is delta-connected on the primary and star connected on the secondary. The primary resistance / phase is 8 Q and secondary resistance/phase is 0.0034 Q. determine the efficiency on full-load at 0.8 power factor lagging if the iron loss is 660 W
Q1-A 3-phase step down transformer 1200 KVA , 11000/2200 V, 50 Hz .The resistance
/phase and leakage reactance/phase of the primary winding are 1.22 and 4.82 and the
corresponding values for the secondary winding are 0.012 and 0.062 respectively if the
primary winding is connected in delta and secondary in star. calculate:
i)The voltage to be applied at normal frequency to the primary to circulate full-load
current through it when the secondary is short-circuited
ii) The full load copper loss
Q2- A 3-phase 250KVA, 11000/416 transformer is delta-connected on the primary and
star connected on the secondary. The primary resistance / phase is 8 2 and secondary
resistance/phase is 0.0034 2. determine the efficiency on full-load at o.8 power factor
lagging if the iron loss is 660 W
03
Transcribed Image Text:Q1-A 3-phase step down transformer 1200 KVA , 11000/2200 V, 50 Hz .The resistance /phase and leakage reactance/phase of the primary winding are 1.22 and 4.82 and the corresponding values for the secondary winding are 0.012 and 0.062 respectively if the primary winding is connected in delta and secondary in star. calculate: i)The voltage to be applied at normal frequency to the primary to circulate full-load current through it when the secondary is short-circuited ii) The full load copper loss Q2- A 3-phase 250KVA, 11000/416 transformer is delta-connected on the primary and star connected on the secondary. The primary resistance / phase is 8 2 and secondary resistance/phase is 0.0034 2. determine the efficiency on full-load at o.8 power factor lagging if the iron loss is 660 W 03
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Single phase transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,