Q.1 A chilling plant has inside dimensions 70 cm length, 50 cm width and 130 cm height. The walls of the chilling plant are 3mm thick. Temperature inside the chilling plant is to be maintained at 4°C. The walls of chilling plant are insulated with fibre glass 75 mm thickness. The outer metal cover is provided over the insulation have 3 mm thickness. The surrounding air temperature is 30°C. Film coefficient of heat transfer at the inner surface of chilling plant and at the outer surface of the chilling plant are 10 W/m2°C and 113.5 W/M2°C respectively.

Computer Networking: A Top-Down Approach (7th Edition)
7th Edition
ISBN:9780133594140
Author:James Kurose, Keith Ross
Publisher:James Kurose, Keith Ross
Chapter1: Computer Networks And The Internet
Section: Chapter Questions
Problem R1RQ: What is the difference between a host and an end system? List several different types of end...
icon
Related questions
Question
Note: Draw neat and label diagram wherever necessary, Assume suitable data if necessary
Q.1 A chilling plant has inside dimensions 70 cm length, 50 cm width and 130 cm height. The
walls of the chilling plant are 3mm thick. Temperature inside the chilling plant is to be
maintained at 4°C. The walls of chilling plant are insulated with fibre glass 75 mm thickness.
The outer metal cover is provided over the insulation have 3 mm thickness. The surrounding air
temperature is 30°C. Film coefficient of heat transfer at the inner surface of chilling plant and at
the outer surface of the chilling plant are 10 W/m2 °C and 113.5 W/m2 °C respectively.
k(metal wall) = 43 W/m °C , k(fibre glass) = 0.035 W/m °C
At steady state operation, Calculate: 1) The rate of removal for chilling plant; 2) The temperature
at the inner and outer surface of insulation; 3) Temperature at the outer surface of metal wall [7]
Transcribed Image Text:Note: Draw neat and label diagram wherever necessary, Assume suitable data if necessary Q.1 A chilling plant has inside dimensions 70 cm length, 50 cm width and 130 cm height. The walls of the chilling plant are 3mm thick. Temperature inside the chilling plant is to be maintained at 4°C. The walls of chilling plant are insulated with fibre glass 75 mm thickness. The outer metal cover is provided over the insulation have 3 mm thickness. The surrounding air temperature is 30°C. Film coefficient of heat transfer at the inner surface of chilling plant and at the outer surface of the chilling plant are 10 W/m2 °C and 113.5 W/m2 °C respectively. k(metal wall) = 43 W/m °C , k(fibre glass) = 0.035 W/m °C At steady state operation, Calculate: 1) The rate of removal for chilling plant; 2) The temperature at the inner and outer surface of insulation; 3) Temperature at the outer surface of metal wall [7]
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Computer Networking: A Top-Down Approach (7th Edi…
Computer Networking: A Top-Down Approach (7th Edi…
Computer Engineering
ISBN:
9780133594140
Author:
James Kurose, Keith Ross
Publisher:
PEARSON
Computer Organization and Design MIPS Edition, Fi…
Computer Organization and Design MIPS Edition, Fi…
Computer Engineering
ISBN:
9780124077263
Author:
David A. Patterson, John L. Hennessy
Publisher:
Elsevier Science
Network+ Guide to Networks (MindTap Course List)
Network+ Guide to Networks (MindTap Course List)
Computer Engineering
ISBN:
9781337569330
Author:
Jill West, Tamara Dean, Jean Andrews
Publisher:
Cengage Learning
Concepts of Database Management
Concepts of Database Management
Computer Engineering
ISBN:
9781337093422
Author:
Joy L. Starks, Philip J. Pratt, Mary Z. Last
Publisher:
Cengage Learning
Prelude to Programming
Prelude to Programming
Computer Engineering
ISBN:
9780133750423
Author:
VENIT, Stewart
Publisher:
Pearson Education
Sc Business Data Communications and Networking, T…
Sc Business Data Communications and Networking, T…
Computer Engineering
ISBN:
9781119368830
Author:
FITZGERALD
Publisher:
WILEY