Problem of the Week 5: Due next Monday, Oct. 14th at the beginning of class. A 6.2179-g sample of sirloin steak was ashed to remove organic materials, and the residue dissolved in a small amount of HCI and diluted to volume in a 50- mL volumetric flask. Iron can be analyzed by atomic absorption at a wavelength of 248.3 nm. A 10.0 mL sample of the dissolved residue is mixed with 1.00 mL of water and the absorbance is measured to be 0.352> A second 10.0 mL sample of the digested steak is mixed with 900.0 μL of water and 100.0 μL of an iron standard containing 250.0 μg Fe/mL. The absorbance of this solution was determined to be 0.613. What is the concentration of iron in the steak in wt %? In ppm?

Fundamentals Of Analytical Chemistry
9th Edition
ISBN:9781285640686
Author:Skoog
Publisher:Skoog
Chapter24: Introduction To Spectrochemical Methods
Section: Chapter Questions
Problem 24.16QAP
icon
Related questions
Question
Please correct answer and don't use hand rating
Problem of the Week 5:
Due next Monday, Oct. 14th at the beginning of class.
A 6.2179-g sample of sirloin steak was ashed to remove organic materials, and
the residue dissolved in a small amount of HCI and diluted to volume in a 50-
mL volumetric flask.
Iron can be analyzed by atomic absorption at a wavelength of 248.3 nm. A
10.0 mL sample of the dissolved residue is mixed with 1.00 mL of water and
the absorbance is measured to be 0.352>
A second 10.0 mL sample of the digested steak is mixed with 900.0 μL of water
and 100.0 μL of an iron standard containing 250.0 μg Fe/mL. The absorbance
of this solution was determined to be 0.613. What is the concentration of
iron in the steak in wt %? In ppm?
Transcribed Image Text:Problem of the Week 5: Due next Monday, Oct. 14th at the beginning of class. A 6.2179-g sample of sirloin steak was ashed to remove organic materials, and the residue dissolved in a small amount of HCI and diluted to volume in a 50- mL volumetric flask. Iron can be analyzed by atomic absorption at a wavelength of 248.3 nm. A 10.0 mL sample of the dissolved residue is mixed with 1.00 mL of water and the absorbance is measured to be 0.352> A second 10.0 mL sample of the digested steak is mixed with 900.0 μL of water and 100.0 μL of an iron standard containing 250.0 μg Fe/mL. The absorbance of this solution was determined to be 0.613. What is the concentration of iron in the steak in wt %? In ppm?
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage
Principles of Modern Chemistry
Principles of Modern Chemistry
Chemistry
ISBN:
9781305079113
Author:
David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:
Cengage Learning