For summer air conditioner application of a room; The sensible heat gain of the room is 13kW, the latent heat gain is 3kW, and the design conditions are determined as 21°C relative humidity 55%. Outdoor air conditions are at 42 °C 35% relative humidity, and the relative humidity of the air passing through the cooling coil at the exit from the coil will be 95%. Since the amount of air blown into the environment is 5000m^3/h, the return air is 700 m^3/h: a-Show the event in the psychometric diagram according to the data of the air conditioning application. b-Find the dry bulb temperature of the air at the outlet of the cooling coil. c-Calculate the amount of air that is bypassed and not by-passed from the coil

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
For summer air conditioner application of a room; The sensible heat gain of the room is
13kW, the latent heat gain is 3kW, and the design conditions are determined as 21°C
relative humidity 55%. Outdoor air conditions are at 42 °C 35% relative humidity, and the
relative humidity of the air passing through the cooling coil at the exit from the coil will
be 95%. Since the amount of air blown into the environment is 5000m^3/h, the return air
is 700 m^3/h:
a- Show the event in the psychometric diagram according to the data of the air
conditioning application.
b-Find the dry bulb temperature of the air at the outlet of the cooling coil.
c-Calculate the amount of air that is bypassed and not by-passed from the coil
B
Mahal
Transcribed Image Text:For summer air conditioner application of a room; The sensible heat gain of the room is 13kW, the latent heat gain is 3kW, and the design conditions are determined as 21°C relative humidity 55%. Outdoor air conditions are at 42 °C 35% relative humidity, and the relative humidity of the air passing through the cooling coil at the exit from the coil will be 95%. Since the amount of air blown into the environment is 5000m^3/h, the return air is 700 m^3/h: a- Show the event in the psychometric diagram according to the data of the air conditioning application. b-Find the dry bulb temperature of the air at the outlet of the cooling coil. c-Calculate the amount of air that is bypassed and not by-passed from the coil B Mahal
Expert Solution
steps

Step by step

Solved in 5 steps with 1 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY