QI: An air conditioning system is used to keep indoor condition of 24°C and 50% relative humidity inside a space as shown in Figure 1. An amount of 75% of returned air is mixed with 25% fresh ambient air at 40°C and 40% relative humidity before entering to the air filter. The air is cooled though the air cooling coil of surface effective temperature (apparatus dew point temperature) equals to 10°C and bypass factor is 0.2. Find the following: a. State of air after mixing (point m). b. State of air at coil outlet (point c). c. Sketch the process on the psychometric chart. d. Sensible heat factor of the space. space exhaust (25%) cooling coil filter fan m fresh air (25%) Figure 1

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
QI: An air conditioning system is used to keep indoor condition of 24°C and 50%
relative humidity inside a space as shown in Figure 1. An amount of 75% of returned
air is mixed with 25% fresh ambient air at 40°C and 40% relative humidity before
entering to the air filter. The air is cooled though the air cooling coil of surface
effective temperature (apparatus dew point temperature) equals to 10°C and bypass
factor is 0.2. Find the following:
a. State of air after mixing (point m).
b. State of air at coil outlet (point c).
c. Sketch the process on the psychometric chart.
d. Sensible heat factor of the space.
space
exhaust (25%)
cooling coil filter
fan
m
fresh air (25%)
Figure 1
Transcribed Image Text:QI: An air conditioning system is used to keep indoor condition of 24°C and 50% relative humidity inside a space as shown in Figure 1. An amount of 75% of returned air is mixed with 25% fresh ambient air at 40°C and 40% relative humidity before entering to the air filter. The air is cooled though the air cooling coil of surface effective temperature (apparatus dew point temperature) equals to 10°C and bypass factor is 0.2. Find the following: a. State of air after mixing (point m). b. State of air at coil outlet (point c). c. Sketch the process on the psychometric chart. d. Sensible heat factor of the space. space exhaust (25%) cooling coil filter fan m fresh air (25%) Figure 1
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY