Figure below shows a power system where load at bus 5 is fed by generators at bus 1 and bus 4. The generators are rated at 100MVA; 11 KV with subtransient reactance of 25%. The transformers are rated each at 100 MVA, 11/112 KV and have a leakage reactance of 8%. The lines have an inductance of 1 mH/phase/km. Line L1 is 100 km long while lines L2 and L3 are each of 50 km in length. ots H 4₁ Load tieto G₂ For a 3-phase fault at bus 5, the fault current is equal to 2530A. What the value of the change in the fault current if the length of L1 is reduced to 50 km (i.e. new .value/old value)

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Figure below shows a power system
where load at bus 5 is fed by
generators
at bus 1 and bus 4. The
generators are rated at 100MVA; 11 KV
with subtransient reactance of 25%.
The transformers are rated each at 100
MVA, 11/112 KV and have a leakage
reactance of 8%. The lines have an
inductance of 1 mH/phase/km. Line L1 is
100 km long while lines L2 and L3 are
each of 50 km in length.
He
Load
10
For a 3-phase fault at bus 5, the
fault current is equal to 2530A.
What the value of the change in
the fault current if the length of
L1 is reduced to 50 km (i.e. new
.value/old value)
1 O
1.0174
0.9965
1.0062
1.0222
0.9867
Transcribed Image Text:Figure below shows a power system where load at bus 5 is fed by generators at bus 1 and bus 4. The generators are rated at 100MVA; 11 KV with subtransient reactance of 25%. The transformers are rated each at 100 MVA, 11/112 KV and have a leakage reactance of 8%. The lines have an inductance of 1 mH/phase/km. Line L1 is 100 km long while lines L2 and L3 are each of 50 km in length. He Load 10 For a 3-phase fault at bus 5, the fault current is equal to 2530A. What the value of the change in the fault current if the length of L1 is reduced to 50 km (i.e. new .value/old value) 1 O 1.0174 0.9965 1.0062 1.0222 0.9867
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Single phase transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,