FAAS Absorbance Readings for Lead Standard Volume Additions Vs (ml) Absorbance at 283 nm; A283 0.00 5.00 10.00 15.00 20.00 0.194 0.349 0.485 0.645 0.789 S 1. Standard Addition A283 vs. Vs Plot for the Lake Water Sample. Plot in EXCEL the A283 vs. V, data. You may find pages 1 - 7 of the Lab 2 Supplement - EXCEL Graphing & LINEST document on D2L particularly helpful. Include the R2 value and the equation of the linear trend-line (both from EXCEL). You will likely need to adjust the sig fig display for the R² value and linear trend-line equation in EXCEL. Properly title the plot and label the axes correctly. Use reasonable sig figs and correct units. Paste in the complete plot below.

Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
icon
Related questions
Question
100%
Standard Addition A283 vs. V s Plot for the Lake Water Sample. Plot in EXCEL the
A283 vs. V s data. Include the R₂ value and the equation of the linear trend-line (both
from EXCEL). You will likely need to adjust the sig fig display for the R₂ value and
linear trend-line equation in EXCEL. Properly title the plot and label the axes
correctly. Use reasonable sig figs and correct units. Paste in the complete plot below.
Transcribed Image Text:Standard Addition A283 vs. V s Plot for the Lake Water Sample. Plot in EXCEL the A283 vs. V s data. Include the R₂ value and the equation of the linear trend-line (both from EXCEL). You will likely need to adjust the sig fig display for the R₂ value and linear trend-line equation in EXCEL. Properly title the plot and label the axes correctly. Use reasonable sig figs and correct units. Paste in the complete plot below.
Instructions. Carefully review the Constant-Volume Standard Addition material (pages 7 - 13) of the CHEM
146 Lab 2 Manual given its central importance (especially the fully worked example on pages 11 - 13). In this
online activity, you are processing and analyzing raw FAAS data identical to what you would obtain in lab.
FAAS Lead Analysis by Constant-Volume Standard Addition. Assume we wish to find the Lead (Pb)
concentration in ppb for a lake water sample (the "unknown"). Using a pipette, 10.00 mL of lake water is
loaded into five 50 mL volumetric flasks. Next, exactly 0.00, 5.00, 10.00, 15.00 and 20.00 mL of standard lead
solution at 4.96 ppb (parts per billion) is added. After dilution to the volume, FAAS readings at λ = 283 nm are
taken of the five solutions. The resulting absorbance values are presented below.
Table 2-1. FAAS Lake Water Sample Lead Analysis.
FAAS Absorbance Readings for Lead Standard Volume Additions
Absorbance at 283 nm; A283
Vs (ml)
S
0.00
5.00
10.00
15.00
20.00
0.194
0.349
0.485
0.645
0.789
S
1. Standard Addition A283 vs. VS Plot for the Lake Water Sample. Plot in EXCEL the A283 vs. V data. You
may find pages 1 - 7 of the Lab 2 Supplement EXCEL Graphing & LINEST document on D2L particularly
helpful. Include the R2 value and the equation of the linear trend-line (both from EXCEL). You will likely need
to adjust the sig fig display for the R² value and linear trend-line equation in EXCEL. Properly title the plot and
label the axes correctly. Use reasonable sig figs and correct units. Paste in the complete plot below.
Transcribed Image Text:Instructions. Carefully review the Constant-Volume Standard Addition material (pages 7 - 13) of the CHEM 146 Lab 2 Manual given its central importance (especially the fully worked example on pages 11 - 13). In this online activity, you are processing and analyzing raw FAAS data identical to what you would obtain in lab. FAAS Lead Analysis by Constant-Volume Standard Addition. Assume we wish to find the Lead (Pb) concentration in ppb for a lake water sample (the "unknown"). Using a pipette, 10.00 mL of lake water is loaded into five 50 mL volumetric flasks. Next, exactly 0.00, 5.00, 10.00, 15.00 and 20.00 mL of standard lead solution at 4.96 ppb (parts per billion) is added. After dilution to the volume, FAAS readings at λ = 283 nm are taken of the five solutions. The resulting absorbance values are presented below. Table 2-1. FAAS Lake Water Sample Lead Analysis. FAAS Absorbance Readings for Lead Standard Volume Additions Absorbance at 283 nm; A283 Vs (ml) S 0.00 5.00 10.00 15.00 20.00 0.194 0.349 0.485 0.645 0.789 S 1. Standard Addition A283 vs. VS Plot for the Lake Water Sample. Plot in EXCEL the A283 vs. V data. You may find pages 1 - 7 of the Lab 2 Supplement EXCEL Graphing & LINEST document on D2L particularly helpful. Include the R2 value and the equation of the linear trend-line (both from EXCEL). You will likely need to adjust the sig fig display for the R² value and linear trend-line equation in EXCEL. Properly title the plot and label the axes correctly. Use reasonable sig figs and correct units. Paste in the complete plot below.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Statistics and Analytical Chemistry
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Organic Chemistry
Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY