b- An evacuated tank ,shown if fig of 1 ft3 is coupled to air supply line through valve .When the valve is opened, the air flow from supply line at 70°F,120 psi until the pressure reaches 90psi . calculate the final temperature and mass inside tank ,assuming the process is adiabatic. R = 53.34 Ibf-ft/lbm °R use the table below in case.

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter40: Typical Operating Conditions
Section: Chapter Questions
Problem 10RQ: The seasonal energy efficiency ratio (SEER) includes the energy used in the _____and _____cycles.
icon
Related questions
Question
b- An evacuated tank ,shown if fig of 1 ft3 is coupled to air supply line through
valve .When the valve is opened, the air flow from supply line at 70°F,120 psi
until the pressure reaches 90psi . calculate the final temperature and mass
inside tank ,assuming the process is adiabatic. R= 53.34 Ibf-ft/lbm °R use the table
below in case.
Alr
supply
line
Tank
Idcat-Gas Propertiles of Air (English Units)0, Standard Entropy at 1 atm = 161.325 kPa = 14.696 1bf/in.²
(R)
(Btulbm)
(Btu/lbm)
(Btu/lbm R)
(R)
(Btu/lbm)
(Btu/lbm) (Btu/Ibm R)
400
68.212
95.634
1.56788
1950
357.243
490.928
1.96404
440
75.047
105.212
1.59071
2000
367.642
504.755
1.97104
480
81.887
114.794
1.61155
2050
378.096
S18.636
1.97790
520
88.733
124.383
1.63074
2100
388.602
532.570
1.98461
536.67
91.589
128.381
1.63831
2150
399.158
546.554
1.99119
540
92.160
129.180
1.63979
2200
409.764
560.588
1.99765
560
95.589
133.980
1.61852
2300
431.114
588.793
2.01018
600
102.457
143.590
1.66510
2400
452.640
617.175
2.02226
1000
172.564
241.121
1.78947
3400
675.396
908.488
2.12361
1040
179.787
251.086
1.79924
3500
698.257
938.204
2.13222
1080
187.058
261.099
1.80868
3600
721.203
958.005
2.14062
1120
194.378
271.161
L81783
3700
744.230
997.888
2.14880
1160
201.748
281.273
1.82670
3800
767.334
1027.848
2.15679
Transcribed Image Text:b- An evacuated tank ,shown if fig of 1 ft3 is coupled to air supply line through valve .When the valve is opened, the air flow from supply line at 70°F,120 psi until the pressure reaches 90psi . calculate the final temperature and mass inside tank ,assuming the process is adiabatic. R= 53.34 Ibf-ft/lbm °R use the table below in case. Alr supply line Tank Idcat-Gas Propertiles of Air (English Units)0, Standard Entropy at 1 atm = 161.325 kPa = 14.696 1bf/in.² (R) (Btulbm) (Btu/lbm) (Btu/lbm R) (R) (Btu/lbm) (Btu/lbm) (Btu/Ibm R) 400 68.212 95.634 1.56788 1950 357.243 490.928 1.96404 440 75.047 105.212 1.59071 2000 367.642 504.755 1.97104 480 81.887 114.794 1.61155 2050 378.096 S18.636 1.97790 520 88.733 124.383 1.63074 2100 388.602 532.570 1.98461 536.67 91.589 128.381 1.63831 2150 399.158 546.554 1.99119 540 92.160 129.180 1.63979 2200 409.764 560.588 1.99765 560 95.589 133.980 1.61852 2300 431.114 588.793 2.01018 600 102.457 143.590 1.66510 2400 452.640 617.175 2.02226 1000 172.564 241.121 1.78947 3400 675.396 908.488 2.12361 1040 179.787 251.086 1.79924 3500 698.257 938.204 2.13222 1080 187.058 261.099 1.80868 3600 721.203 958.005 2.14062 1120 194.378 271.161 L81783 3700 744.230 997.888 2.14880 1160 201.748 281.273 1.82670 3800 767.334 1027.848 2.15679
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Forms of Energy
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning