An air conditioning system is designed under the following conditions Ourdoor conditions; 30°C dbt, 75% RH Required indoor conditions; 22°C dbt, 70% RH Amount of free air circulated; 3.33 m/sec Coil dew point temperature; 14°C Therequired condition is achieved first by cooling and dehumi dification and then by Teating. Estimate (1) Capacity of cooling coil intons and its efficiency. ii) Capacity of heating coil in kW. ii) Amount of water vapour removed kg/sec,
An air conditioning system is designed under the following conditions Ourdoor conditions; 30°C dbt, 75% RH Required indoor conditions; 22°C dbt, 70% RH Amount of free air circulated; 3.33 m/sec Coil dew point temperature; 14°C Therequired condition is achieved first by cooling and dehumi dification and then by Teating. Estimate (1) Capacity of cooling coil intons and its efficiency. ii) Capacity of heating coil in kW. ii) Amount of water vapour removed kg/sec,
Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter2: Matter And Energy
Section: Chapter Questions
Problem 15RQ: Why is information regarding the specific volume of gases important to the designer of...
Related questions
Question
![An air conditioning system is designed under the following conditions
Outdoor conditions; 30°C dbt, 75% RH
Required indoor conditions; 22°C dbt, 70% RH
Amount of free air circulated; 3.33 m/sec
Coil dew point temperature; 14°C
The required condition is achieved first by cooling and dehumi dification and then by
heating. Estimate
(1) Capacity of cooling coil intons and its efficiency.
(ii) Capacity of heating coil in kW.
ii) Amount of water vapour removed kg/sec.](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2Fd4a9ffa9-f70a-42eb-ab36-0054c1b77643%2Fa4370b1d-8766-4f9d-9dc2-b0e20ea497e3%2Fltc97n_processed.jpeg&w=3840&q=75)
Transcribed Image Text:An air conditioning system is designed under the following conditions
Outdoor conditions; 30°C dbt, 75% RH
Required indoor conditions; 22°C dbt, 70% RH
Amount of free air circulated; 3.33 m/sec
Coil dew point temperature; 14°C
The required condition is achieved first by cooling and dehumi dification and then by
heating. Estimate
(1) Capacity of cooling coil intons and its efficiency.
(ii) Capacity of heating coil in kW.
ii) Amount of water vapour removed kg/sec.
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 3 steps with 3 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
![Refrigeration and Air Conditioning Technology (Mi…](https://www.bartleby.com/isbn_cover_images/9781305578296/9781305578296_smallCoverImage.gif)
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning
![Refrigeration and Air Conditioning Technology (Mi…](https://www.bartleby.com/isbn_cover_images/9781305578296/9781305578296_smallCoverImage.gif)
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning