Q.1// A conference room is to be air conditioned for comfort conditions of (25°C) DBT and (50% RH). The outdoor air conditions are (35°C DBT) and (28°C WBT). The sensible and latent heat are (43200 kJ/hr) and (36000 kJ/hr) respectively. The return air from the conference room is mixed with outdoor air before entering the cooling coil as shown in the Figure below. In addition, the return air from the (conference room) is mixed with cooling air (after cooling coil) see Figure below, where cooling coil by bass factor (BPF = 0.1) and (ADP =10°C). The air is reheated to (21°C DBT) before supplying to room. Note: point 6 not equal to point 1. Determine: 1- Conditions at point 3 (DBT3, WBT3, RH3, h3). 2- Conditions at point 4 (DBT4, WBT4, RH4, h4). 3- Conditions at point 5 (DBT5, WBT3, RH5, hs). 4 - Conditions at point 6 (WBT6, RH6, h6). 5- The total quantity of air supplied to conference room (kg/sec). 6- Capacity of reheated coil (kJ/kg). 7- Sensible heat factor SHF. 8 - Capacity of cooling coil (kJ/kg). 9 - Contact factor of cooling coil. 10 – Sketch the process on the Psychometric chart. REHEATER SUPPLY AIR Cooling coil VENTED AIR FRESH AIR FAN- CONDITIONED SPACE 3 4 2 conference room 1 kg 1 kg 1 kg 5 kg 11 3 kg
Q.1// A conference room is to be air conditioned for comfort conditions of (25°C) DBT and (50% RH). The outdoor air conditions are (35°C DBT) and (28°C WBT). The sensible and latent heat are (43200 kJ/hr) and (36000 kJ/hr) respectively. The return air from the conference room is mixed with outdoor air before entering the cooling coil as shown in the Figure below. In addition, the return air from the (conference room) is mixed with cooling air (after cooling coil) see Figure below, where cooling coil by bass factor (BPF = 0.1) and (ADP =10°C). The air is reheated to (21°C DBT) before supplying to room. Note: point 6 not equal to point 1. Determine: 1- Conditions at point 3 (DBT3, WBT3, RH3, h3). 2- Conditions at point 4 (DBT4, WBT4, RH4, h4). 3- Conditions at point 5 (DBT5, WBT3, RH5, hs). 4 - Conditions at point 6 (WBT6, RH6, h6). 5- The total quantity of air supplied to conference room (kg/sec). 6- Capacity of reheated coil (kJ/kg). 7- Sensible heat factor SHF. 8 - Capacity of cooling coil (kJ/kg). 9 - Contact factor of cooling coil. 10 – Sketch the process on the Psychometric chart. REHEATER SUPPLY AIR Cooling coil VENTED AIR FRESH AIR FAN- CONDITIONED SPACE 3 4 2 conference room 1 kg 1 kg 1 kg 5 kg 11 3 kg
Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
Related questions
Question
None
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 2 steps with 3 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY