A power station has to meet the following load demand : Load A Load B Load C 50 kW 30 kW 20 kW between between between 10 A.M. and 6 P.M. 6 P.M. and 10 P.M. 4 P.M. and 10 A.M. Plot the daily load curve and determine (i) diversity factor (ii) units generated per day (iii) load factor. A generating station supplies the following loads: 15000 kW, 12000 kW, 8500 kW, 6000 kW and 450 kW. The station has a maximum demand of 22000 kW. The annual load factor of the station is 48%. Calculate (i) the number of units supplied annually (ii) the diversity factor and (iii) the demand factor.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.16P: A single-phase, 120V(rms),60Hz source supplies power to a series R-L circuit consisting of R=10 and...
icon
Related questions
Question

Please help me

A power station has to meet the following load demand :
Load A
Load B
Load C
50 kW
30 kW
20 kW
between
between
between
10 A.M. and 6 P.M.
6 P.M. and 10 P.M.
4 P.M. and 10 A.M.
Plot the daily load curve and determine (i) diversity factor (ii) units generated per day (iii) load factor.
A generating station supplies the following loads: 15000 kW, 12000 kW, 8500 kW, 6000 kW and 450
kW. The station has a maximum demand of 22000 kW. The annual load factor of the station is 48%.
Calculate (i) the number of units supplied annually (ii) the diversity factor and (iii) the demand factor.
Transcribed Image Text:A power station has to meet the following load demand : Load A Load B Load C 50 kW 30 kW 20 kW between between between 10 A.M. and 6 P.M. 6 P.M. and 10 P.M. 4 P.M. and 10 A.M. Plot the daily load curve and determine (i) diversity factor (ii) units generated per day (iii) load factor. A generating station supplies the following loads: 15000 kW, 12000 kW, 8500 kW, 6000 kW and 450 kW. The station has a maximum demand of 22000 kW. The annual load factor of the station is 48%. Calculate (i) the number of units supplied annually (ii) the diversity factor and (iii) the demand factor.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning