A large warehouse was recently constructed in Winnellie with large portal frames spaced at 6m centers supported on pad footings. After construction of the warehouse, it was found that one footing had settled by 35mm but the two adjacent footings had only settled by 5mm and 12mm. (a) Determine the maximum differential settlement. (b) Determine the maximum angular distortion. (c) If the limit for angular distortion for structural damage on this project is 1/250 is the value from (b) acceptable? Give a brief comment. (d) What will be the maximum values of differential settlement for architectural damage (1/350) and for structural damage (1/250) for this project?

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
A large warehouse was recently constructed in Winnellie with large portal frames spaced at 6m
centers supported on pad footings. After construction of the warehouse, it was found that one
footing had settled by 35mm but the two adjacent footings had only settled by 5mm and 12mm.
(a) Determine the maximum differential settlement.
(b) Determine the maximum angular distortion.
(c) If the limit for angular distortion for structural damage on this project is 1/250 is the value
from (b) acceptable? Give a brief comment.
(d) What will be the maximum values of differential settlement for architectural damage (1/350)
and for structural damage (1/250) for this project?.
Transcribed Image Text:A large warehouse was recently constructed in Winnellie with large portal frames spaced at 6m centers supported on pad footings. After construction of the warehouse, it was found that one footing had settled by 35mm but the two adjacent footings had only settled by 5mm and 12mm. (a) Determine the maximum differential settlement. (b) Determine the maximum angular distortion. (c) If the limit for angular distortion for structural damage on this project is 1/250 is the value from (b) acceptable? Give a brief comment. (d) What will be the maximum values of differential settlement for architectural damage (1/350) and for structural damage (1/250) for this project?.
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Methods to Determine Vertical Stress
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning