a) For a bolted assembly with ten bolts, the stafiness of each bolt is ka= 10 MN/m and the stiffness of the members is ku 26 MN/mm per bolt. The joint is subject to occasional disassembly for maistenance and should be preloaded accordingly Assume the external Inad is equally distributed to all the belts. IR has been determined to use Mo 1 cdass 58 bolts with rulled threads. (a) Determine the manimum external load Paa that can be applied to the entire joint without exceeding the proof strength of the boits (b) Determine the maximum esternal lad Pan that can be applied ta the entire joint without causing the members te come out of compression b) A holding fisture for a workpiece 375 mm thick at the clamp locations is being designed. The detail of ane of the clamps in shown in the figure (Problem 10-2. A spring is eequired to drive the clamp upward when removing theworkpiece with a starting force of 65 N. The clamp screw has an M10 - 125 thread. Allow a diametral clearance of 1.25 mm between it and the uncompressed spring it is further specified that the free length of the spring should be Las 48 mm, the solid height La s 31.5 mm, and the safety factor when dosed selid should be n.a 12 Starting with d-2 mm, design a suitable helical coll compression spring for this fixture. Wire diameters are available in 0.2-mm increments hetween 02 to 32 mm.

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
Question two
a) For a bolted assembly with ten bolts, the stiffness of each bolt is a= 10 MN/
and the stiffness of the members is ku 26 MN/mm per bolt. The joint is subject
to occasional disassembly for maintenance and should be preloaded accordingly.
Assume the external load is equally distributed to all the bolts. IR has been
determined to use M6 1 dass S8 bolts with rolled threads.
(a) Determine the maximum external load Paa that can be applied to the entire
joint without exceeding the proof strength of the boits.
(b) Determine the maximum esternal load Pn that can be applied ta the entire
joint without causing the members te come out of compression
b) A holding fixture for a workpiece 37.5 mm thick at the clamp locations is being
designed. The detailof ane of the clamps is shown in the figure (Problem 10-2).
A spring is required to drive the clamp upward when removing the workpiece
with a starting force of 65 N. The clamp screw has an M10 - 125 thread. Allowa
diametral clearance of 1.25 mm between it and the uncompressed spring it is
farther specified that the free length of the spring should be Las 48 mm, the
solid height La s 315 mm, and the safety factor when desed selid should be na
12 Starting with d 2 mm, design a suitable helical coll compression spring for
this fisture. Wire diameters are available in 0.2-mm increments hetween 02 to
12 mm.
Spealt
Probiem 10-23
Warigi
Transcribed Image Text:Question two a) For a bolted assembly with ten bolts, the stiffness of each bolt is a= 10 MN/ and the stiffness of the members is ku 26 MN/mm per bolt. The joint is subject to occasional disassembly for maintenance and should be preloaded accordingly. Assume the external load is equally distributed to all the bolts. IR has been determined to use M6 1 dass S8 bolts with rolled threads. (a) Determine the maximum external load Paa that can be applied to the entire joint without exceeding the proof strength of the boits. (b) Determine the maximum esternal load Pn that can be applied ta the entire joint without causing the members te come out of compression b) A holding fixture for a workpiece 37.5 mm thick at the clamp locations is being designed. The detailof ane of the clamps is shown in the figure (Problem 10-2). A spring is required to drive the clamp upward when removing the workpiece with a starting force of 65 N. The clamp screw has an M10 - 125 thread. Allowa diametral clearance of 1.25 mm between it and the uncompressed spring it is farther specified that the free length of the spring should be Las 48 mm, the solid height La s 315 mm, and the safety factor when desed selid should be na 12 Starting with d 2 mm, design a suitable helical coll compression spring for this fisture. Wire diameters are available in 0.2-mm increments hetween 02 to 12 mm. Spealt Probiem 10-23 Warigi
Expert Solution
steps

Step by step

Solved in 5 steps with 5 images

Blurred answer
Knowledge Booster
Fasteners and Design of Non Permanent Joints
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher: