9.9 Calculate the rms value of the induced emf per phase of a 10-pole, 3-phase 50 Hz Alternator with 2 slots per pole per phase and 4 conductors per slot. Coil span= 150° and the flux per pole = 0.051 Wb. [Ans: 422.17]

Delmar's Standard Textbook Of Electricity
7th Edition
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Stephen L. Herman
Chapter31: Three-phase Alternators
Section: Chapter Questions
Problem 1RQ: What conditions must be met before two alternators can be paralleled together?
icon
Related questions
Question
9.9 Calculate the rms value of the induced emf per phase of a 10-pole, 3-phase
50 Hz Alternator with 2 slots per pole per phase and 4 conductors per slot. Coil
span=
150° and the flux per pole = 0.051 Wb.
[Ans: 422.17]
Transcribed Image Text:9.9 Calculate the rms value of the induced emf per phase of a 10-pole, 3-phase 50 Hz Alternator with 2 slots per pole per phase and 4 conductors per slot. Coil span= 150° and the flux per pole = 0.051 Wb. [Ans: 422.17]