Installing Non-Metallic Sheathed Cable
Objectives
:
To understand all theory reviewed and wire a basic receptacle and lighting circuit using NMD90
cable.
To correctly wire a 120-volt lighting and receptacle control circuit using the provided lab
material.
Materials
&
Tools
Required
:
●
#14/2 NMD90 Cable (Romex)
●
Linesmen Pliers
●
S1 Romex Staples
●
Diagonal Pliers
●
1/2” Plastic Romex Connectors
●
Needle-nose Pliers
●
Electrical Boxes
●
Screwdrivers (Various)
●
120 V 15A Receptacles
●
Wire Strippers
●
120 V 15A Switches
●
Marrettes
●
120 V 15A Breaker
●
Deck Screws
NOTE: Do not install any improper or damaged components. Wiring must be performed to meet
current electrical code requirements.
Installation
Instructions
:
Install NMSC from the breaker panel to the required outlet boxes.
Be sure to install according to the CEC rules. (i.e., points of support, correct length of wire in box).
Connect switch to control a lamp,
Connect a receptacle.
Connect to panel with correct size breaker.
Have instructor review finished connections.
Instructor will then “Power On” completed circuit to allow for circuit testing.
Answer all questions for this lab listed below.
Page 2
of 3
Questions
: State the CEC rule number if the code book is used.
1.
Would the circuit still work if you used the white wire for power and black for neutral?
Definitely yes, the Circuit will work properly because both conductors are the same from the inside, only difference is the color of the insulation. However, it will be an unsafe practice and it also violates electrical standards. It may also mislead another installer. 2.
List another name for the identified conductor?
Identified conductors can also as ground circuit conductor or neutral.
3.
Why are the terminals of the lamp holder colour coded?
Because it helps you to match each wire to the correct terminal. In that holder center is for hot wire and the outer one is for neutral. 4.
What are the distances NMSC cable need to be supported (stapled) when run between boxes
according to the CEC? Show the Code Rule.
As per rule 12-510(2) in the electrical code book, we should give support to the conductor after every 1.5m from the junction box to the destination. 5.
Which conductors (hot, ground or neutral) are always connected to the light switches?
we connect the hot wire to the light switch to open and close the circuit.
Page 3
of 3
LAB MARK
QUESTIONS
TOTAL MARK
10
5
15
Instructor Signature
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
- Access to all documents
- Unlimited textbook solutions
- 24/7 expert homework help
Page 4
of 3
Related Documents
Related Questions
a.1. A main bonding jumper must only be foundA. within enclosures serving as sub-panels.B. at the grounding electrode.C. on the load side of a GFCI.D. within the enclosure that houses the service disconnecting device.a.2. Which of the following statements about grounding electrode conductors is true?A. They restrict the ground connection.B. They eliminate potential differences between conductive objects and the Earth electrode.C. They facilitate operation of overcurrent protective devices.D. They perform bonding between the Earth and grounded conductors.a.3. Main bonding jumpers are required to be made of _______ or other corrosion-resistant material.A. brassB. aluminumC. copperD. copper-clad aluminum
arrow_forward
7.B. The size of a grounding electrode conductor for a service or separately derived system is generally basedon the size of the largestA. ungrounded supply conductor.B. equipment grounding conductor.C. grounded electrode.D. bonding jumper.7.C. Which of the following statements about bonding is true?A. The joint or termination must offer opposition in the circuit for effective electrical connections.B. Effective bonding keeps impedance high if a fault should occur.C. The entire electrical safety circuit is only as good as its strongest bonded link.D. Bonding connections must endure high levels of fault current until overcurrent protective devices can operate.
arrow_forward
8. You're installing type AC cable. The armor coating of type AC cable is allowed for use as an equipmentgrounding conductor (EGC) because of itsA. liquid-tight fittings listed for EGC purposes.B. interlocking ribs that form a complete circuit.C. internal bare bonding strip.D. internal bare aluminum bonding conductor.
arrow_forward
Airframe Electrical System
Question: By what means should aircraft electrical circuits/wires be protected from excessive current?
(Source: FAA AC 43.13-1B/2B)
arrow_forward
schedules are typically provided to detail the circuits and overcurrent protection required for
listribution equipment.
Branch-circuit
- Outlet
C.
d.
ore distribution points for electrical in ....
Switch
Panelboard
arrow_forward
Write the methods of Neutral Grounding.
arrow_forward
What type of terminal seal is shown here?
O Matte
68659
Cable
Wire
Interface
arrow_forward
A snap switch with integral nonmetallic enclosure complying with NEC 300.15(E) is required to be connected to an equipment grounding conductor.
A. True
B. False
arrow_forward
What are the steps for plotting points on microstation uisng offset, station, side and elevation?
arrow_forward
16. A conductor installed from a bonding/grounding bushing that's used to provide a conducting connectionbetween a raceway and the enclosure that the raceway is connected to is an example of a/anA. grounding electrode conductor.B. bonding jumper.C. equipment grounding conductor.D. impedance device.
arrow_forward
Which of the following statements about equipment grounding conductors (EGCS) is true?
A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor.
B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray.
C. No current should be present in the EGC during normal operation.
D. EGCs are required to be decreased in size to address voltage drop.
arrow_forward
Which of the following statements about equipment grounding conductors (EGCs) is true?A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor.B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray.C. No current should be present in the EGC during normal operation.D. EGCs are required to be decreased in size to address voltage drop.
arrow_forward
4. What can installation records be used to determine while servicing equipment?A. Broken connectors in a cable linkB. Problems due to aging during operationC. Broken fiberD. Decreased bending radius during operation
arrow_forward
A 12/2 Type NM copper used for small-appliance branch circuit
ampacity=maximum fuse or circuit breaker size=
arrow_forward
SEE MORE QUESTIONS
Recommended textbooks for you

EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Related Questions
- a.1. A main bonding jumper must only be foundA. within enclosures serving as sub-panels.B. at the grounding electrode.C. on the load side of a GFCI.D. within the enclosure that houses the service disconnecting device.a.2. Which of the following statements about grounding electrode conductors is true?A. They restrict the ground connection.B. They eliminate potential differences between conductive objects and the Earth electrode.C. They facilitate operation of overcurrent protective devices.D. They perform bonding between the Earth and grounded conductors.a.3. Main bonding jumpers are required to be made of _______ or other corrosion-resistant material.A. brassB. aluminumC. copperD. copper-clad aluminumarrow_forward7.B. The size of a grounding electrode conductor for a service or separately derived system is generally basedon the size of the largestA. ungrounded supply conductor.B. equipment grounding conductor.C. grounded electrode.D. bonding jumper.7.C. Which of the following statements about bonding is true?A. The joint or termination must offer opposition in the circuit for effective electrical connections.B. Effective bonding keeps impedance high if a fault should occur.C. The entire electrical safety circuit is only as good as its strongest bonded link.D. Bonding connections must endure high levels of fault current until overcurrent protective devices can operate.arrow_forward8. You're installing type AC cable. The armor coating of type AC cable is allowed for use as an equipmentgrounding conductor (EGC) because of itsA. liquid-tight fittings listed for EGC purposes.B. interlocking ribs that form a complete circuit.C. internal bare bonding strip.D. internal bare aluminum bonding conductor.arrow_forward
- Airframe Electrical System Question: By what means should aircraft electrical circuits/wires be protected from excessive current? (Source: FAA AC 43.13-1B/2B)arrow_forwardschedules are typically provided to detail the circuits and overcurrent protection required for listribution equipment. Branch-circuit - Outlet C. d. ore distribution points for electrical in .... Switch Panelboardarrow_forwardWrite the methods of Neutral Grounding.arrow_forward
- What type of terminal seal is shown here? O Matte 68659 Cable Wire Interfacearrow_forwardA snap switch with integral nonmetallic enclosure complying with NEC 300.15(E) is required to be connected to an equipment grounding conductor. A. True B. Falsearrow_forwardWhat are the steps for plotting points on microstation uisng offset, station, side and elevation?arrow_forward
- 16. A conductor installed from a bonding/grounding bushing that's used to provide a conducting connectionbetween a raceway and the enclosure that the raceway is connected to is an example of a/anA. grounding electrode conductor.B. bonding jumper.C. equipment grounding conductor.D. impedance device.arrow_forwardWhich of the following statements about equipment grounding conductors (EGCS) is true? A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor. B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray. C. No current should be present in the EGC during normal operation. D. EGCs are required to be decreased in size to address voltage drop.arrow_forwardWhich of the following statements about equipment grounding conductors (EGCs) is true?A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor.B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray.C. No current should be present in the EGC during normal operation.D. EGCs are required to be decreased in size to address voltage drop.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios