Fundamentals Of Thermal-fluid Sciences In Si Units
Fundamentals Of Thermal-fluid Sciences In Si Units
5th Edition
ISBN: 9789814720953
Author: Yunus Cengel, Robert Turner, John Cimbala
Publisher: McGraw-Hill Education
bartleby

Videos

Question
Book Icon
Chapter 6, Problem 74P
To determine

The mass flow rate of the refrigerant.

Expert Solution & Answer
Check Mark

Explanation of Solution

Given:

The inlet pressure of Refrigerant (P1) is 1 MPa.

The inlet temperature of Refrigerant  (T1) is 90°C.

The outlet pressure of Refrigerant  (P2) is 1 MPa.

The outlet temperature of Refrigerant  (T2) is 30°C.

The inlet pressure of air (P3) is 100 kPa.

The inlet temperature of air (T3) is 27°C.

The outlet pressure of air (P4) is 95 kPa.

The outlet temperature of air (T4) is 60°C.

Calculation:

Consider the system is in steady state. Hence, the inlet and exit mass flow rates are equal.

The mass flow rate of air (m˙a) is as follows.

  m˙3=m˙4=m˙a

The mass flow rate of refrigerant (m˙R) is as follows.

  m˙1=m˙2=m˙R

Write the energy rate balance equation for one inlet and one outlet system.

  [Q˙1+W˙1+m˙(h1+V122+gz1)][Q˙2+W˙2+m˙(h2+V222+gz2)]=ΔE˙system        (I)

Here, the rate of heat transfer is Q˙, the rate of work transfer is W˙, the enthalpy is h and the velocity is V, the gravitational acceleration is g, the elevation from the datum is z and the rate of change in net energy of the system is ΔE˙system; the suffixes 1 and 2 indicates the inlet and outlet of the system.

The system is at steady state. Hence, the rate of change in net energy of the system becomes zero.

  ΔE˙system=0

Neglect the work transfer, heat transfer to the surrounding, potential and kinetic energies.

The Equations (I) reduced as follows for refrigerant .

  [0+0+m˙1(h1+0+0)][0+0+m˙2(h2+0+0)]=0m˙1h1m˙2h2=0m˙1h1=m˙2h2        (II)

The Equations (I) reduced as follows for air.

  [0+0+m˙3(h3+0+0)][0+0+m˙4(h4+0+0)]=0m˙3h3m˙4h4=0m˙3h3=m˙4h4        (III)

Combining Equation (II) and (III).

  m˙1h1+m˙3h3=m˙2h2+m˙4h4m˙2h2m˙1h1=m˙3h3m˙4h4

Substitute m˙R=m˙1,m˙2 and m˙a=m˙3,m˙4 in the above equation.

  m˙ah4m˙ah3=m˙Rh1m˙Rh2m˙a(h4h3)=m˙R(h1h2)m˙R=m˙a(h4h3)h1h2        (IV)

Write the formula for change in enthalpy (h4h3) of air.

  h4h3=cp,a(T4T3)

Substitute h4h3=cp,a(T4T3) in Equation (IV).

  m˙R=m˙a[cp,a(T4T3)]h1h2=m˙acp,a(T4T3)h1h2        (V)

For refrigerant:

At inlet:

The refrigerant is at the state of superheated condition.

Refer Table A-13, “Superheated refrigerant-134a”.

Obtain the inlet enthalpy (h1) corresponding to the pressure of 1MPa and the temperature of 90°C.

  h1=324.66kJ/kg

At exit:

The refrigerant is at the state of saturated liquid.

Refer Table A-11, “Saturated refrigerant-134a-Temperature table”.

Obtain the exit enthalpy (h2) corresponding to the temperature of 30°C.

  hf=h2=93.58kJ/kg

For air:

Refer Table A-1, “Molar mass, gas constant, and critical-point properties”.

The gas constant of air (R) is 0.287kPam3/kgK.

Refer Table A-2, “Ideal2gas specific heats of various common gases”.

The specific heat at constant pressure (cp@300K) at the temperature of 300K is 1.005kJ/kg°C.

Write the formula for mass flow rate of air (m˙a).

  m˙a=V˙P3RT3        (VI)

Here, the volumetric flow rate of air is V˙, the pressure is P, the gas constant of air is R and the temperature is T; the suffix one indicates the inlet condition of air.

Conclusion:

Substitute V˙=600m3/min, P3=100kPa, R=0.287kPam3/kgK and T3=27°C in Equation (VI).

  m˙air=(600m3/min)(100kPa)(0.287kPam3/kgK)(27°C)=60000kPam3/min(0.287kPam3/kgK)(27+273)K=60000kPam3/min86.1kPam3/kg=696.8641kg/min

Substitute m˙a=696.8641kg/min, cp,a=1.005kJ/kg°C, T4=60°C, T3=27°C, h1=324.66kJ/kg, h2=93.58kJ/kg in Equation (V).

  m˙R=(696.8641kg/min)(1.005kJ/kg°C)(60°C27°C)324.66kJ/kg93.58kJ/kg=(696.8641kg/min)(1.005kJ/kg°C)(33K)231.08=23111.4979kJ/min231.08kJ/kg=100.0151kg/min

  =100kg/min

Thus, the mass flow rate of the refrigerant is 100kg/min.

Want to see more full solutions like this?

Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
Assignment 10, Question 4, Problem Book #202 Problem Statement An ideal Brayton cycle with a two-stage compressor, a two-stage turbine, and a regenerator operates with a mass flow rate of 25 kg/s. The regenerator cold inlet is at 490 K and its effectiveness is 60%. Ambient conditions are 90 kPa and 20°C. The intercooler operates at 450 kPa and the reheater operates at 550 kPa. The temperature at the exit of the combustion chamber is 1,400 K. Heat is removed in the intercooler at a rate of 2.5 MW and heat is added in the reheater at a rate of 10 MW. Determine the thermal efficiency and the back work ratio. Use a cold air standard analysis with cp = 1.005 kJ/(kg K) and k = 1.4. . Answer Table Stage Description Your Answer Correct Answer Due Date Grade (%) 1 Thermal efficiency (%) Dec 5, 2024 11:59 pm 0.0 1 Weight Attempt Action/Message 1/5 Part Type Submit 1 Back work ratio (%) Dec 5, 2024 11:59 pm 0.0 1 * Correct answers will only show after due date has passed.
Assignment 10, Question 3, Problem Book #198 Problem Statement Consider a Brayton cycle with a regenerator. The regenerator has an effectiveness of 75%. The compressor inlet conditions are 1.2 bar and 300 K and the mass flowrate is 4.5 kg/s. The compressor outlet pressure is 9 bar. Both the compressor and turbine consist of a single isentropic stage. What minimum power output must be achieved before the regenerator begins to have a benefit? Use an air-standard analysis. Answer Table Correct Answer Stage Description Your Answer Due Date Grade (%) Part Weight Attempt Action/Message Туре 1 Power output (MW) Dec 5, 2024 11:59 pm 0.0 1 1/5 Submit * Correct answers will only show after due date has passed.
Q-3 Consider an engine operating on the ideal Diesel cycle with air as the working fluid. The volume of the cylinder is 1200 cm³ at the beginning of the Compression process, 75 cm³ at the end, and 150 cm³ after the heat addition process. Air is at 17°c and lookpa at the beginning of the compression proc ess. Determine @ The pressure at the beginning of the heat rejection process. the net work per cycle in kjⒸthe mean effective pressur. Answers @264.3 KN/m² ②0.784 kj or 544-6 kj © 697 KN 19 2 m

Chapter 6 Solutions

Fundamentals Of Thermal-fluid Sciences In Si Units

Ch. 6 - Prob. 11PCh. 6 - Prob. 12PCh. 6 - Prob. 13PCh. 6 - Prob. 14PCh. 6 - Prob. 15PCh. 6 - Prob. 16PCh. 6 - A house is maintained at 1 atm and 24°C, and warm...Ch. 6 - Prob. 18PCh. 6 - Prob. 19PCh. 6 - Prob. 20PCh. 6 - Prob. 21PCh. 6 - The kinetic energy of a fluid increases as it is...Ch. 6 - Prob. 23PCh. 6 - Air enters a nozzle steadily at 50 psia, 140°F,...Ch. 6 - Prob. 25PCh. 6 - Prob. 26PCh. 6 - Air at 600 kPa and 500 K enters an adiabatic...Ch. 6 - Prob. 28PCh. 6 - Prob. 29PCh. 6 - Air at 13 psia and 65°F enters an adiabatic...Ch. 6 - Prob. 31PCh. 6 - Prob. 32PCh. 6 - Prob. 33PCh. 6 - Steam at 4 MPa and 400°C enters a nozzle steadily...Ch. 6 - Prob. 35PCh. 6 - Prob. 36PCh. 6 - Prob. 37PCh. 6 - Prob. 38PCh. 6 - Prob. 39PCh. 6 - Prob. 40PCh. 6 - Prob. 41PCh. 6 - Prob. 42PCh. 6 - Prob. 43PCh. 6 - Helium is to be compressed from 105 kPa and 295 K...Ch. 6 - Carbon dioxide enters an adiabatic compressor at...Ch. 6 - Air is compressed from 14.7 psia and 60°F to a...Ch. 6 - Prob. 47PCh. 6 - An adiabatic gas turbine expands air at 1300 kPa...Ch. 6 - Steam flows steadily into a turbine with a mass...Ch. 6 - Prob. 50PCh. 6 - Prob. 51PCh. 6 - Prob. 52PCh. 6 - Prob. 53PCh. 6 - Prob. 54PCh. 6 - Refrigerant-134a is throttled from the saturated...Ch. 6 - Prob. 56PCh. 6 - Prob. 57PCh. 6 - Prob. 58PCh. 6 - Prob. 59PCh. 6 - Prob. 60PCh. 6 - Prob. 61PCh. 6 - Prob. 62PCh. 6 - Prob. 63PCh. 6 - Prob. 64PCh. 6 - Prob. 65PCh. 6 - Prob. 66PCh. 6 - Prob. 67PCh. 6 - Prob. 68PCh. 6 - Prob. 69PCh. 6 - Prob. 70PCh. 6 - A thin-walled double-pipe counter-flow heat...Ch. 6 - Prob. 72PCh. 6 - Prob. 73PCh. 6 - Prob. 74PCh. 6 - Prob. 75PCh. 6 - Prob. 77PCh. 6 - Prob. 78PCh. 6 - Prob. 79PCh. 6 - Prob. 80PCh. 6 - Prob. 81PCh. 6 - Prob. 82PCh. 6 - Prob. 83PCh. 6 - Prob. 84PCh. 6 - Prob. 85PCh. 6 - The components of an electronic system dissipating...Ch. 6 - Prob. 87PCh. 6 - Prob. 88PCh. 6 - Prob. 89PCh. 6 - Prob. 90PCh. 6 - Prob. 91PCh. 6 - Prob. 92PCh. 6 - Prob. 93PCh. 6 - A house has an electric heating system that...Ch. 6 - Prob. 95PCh. 6 - Refrigerant-134a enters the condenser of a...Ch. 6 - Prob. 97PCh. 6 - Prob. 98PCh. 6 - Prob. 99PCh. 6 - Prob. 100PCh. 6 - Air enters the duct of an air-conditioning system...Ch. 6 - Prob. 102PCh. 6 - A rigid, insulated tank that is initially...Ch. 6 - Prob. 105PCh. 6 - Prob. 106PCh. 6 - Prob. 107PCh. 6 - Prob. 108PCh. 6 - Prob. 109PCh. 6 - An air-conditioning system is to be filled from a...Ch. 6 - Prob. 111PCh. 6 - A 0.06-m3 rigid tank initially contains...Ch. 6 - A 0.3-m3 rigid tank is filled with saturated...Ch. 6 - Prob. 114PCh. 6 - A 0.3-m3 rigid tank initially contains...Ch. 6 - Prob. 116PCh. 6 - Prob. 117PCh. 6 - An insulated 40-ft3 rigid tank contains air at 50...Ch. 6 - A vertical piston–cylinder device initially...Ch. 6 - A vertical piston–cylinder device initially...Ch. 6 - The air in a 6-m × 5-m × 4-m hospital room is to...Ch. 6 - Prob. 124RQCh. 6 - Prob. 125RQCh. 6 - Prob. 126RQCh. 6 - Prob. 127RQCh. 6 - Prob. 128RQCh. 6 - Prob. 129RQCh. 6 - Prob. 130RQCh. 6 - Prob. 131RQCh. 6 - Prob. 132RQCh. 6 - Steam enters a nozzle with a low velocity at 150°C...Ch. 6 - Prob. 134RQCh. 6 - Prob. 135RQCh. 6 - Prob. 136RQCh. 6 - In large steam power plants, the feedwater is...Ch. 6 - Prob. 138RQCh. 6 - Prob. 139RQCh. 6 - Prob. 140RQCh. 6 - Prob. 141RQCh. 6 - Prob. 142RQCh. 6 - Prob. 143RQCh. 6 - Prob. 144RQCh. 6 - Prob. 145RQCh. 6 - Prob. 146RQCh. 6 - Repeat Prob. 6–146 for a copper wire ( = 8950...Ch. 6 - Prob. 148RQCh. 6 - Prob. 149RQCh. 6 - Prob. 150RQCh. 6 - Prob. 151RQCh. 6 - Prob. 152RQCh. 6 - Prob. 153RQCh. 6 - An adiabatic air compressor is to be powered by a...Ch. 6 - Prob. 156RQCh. 6 - Prob. 157RQCh. 6 - Prob. 158RQCh. 6 - Prob. 159RQCh. 6 - Prob. 160RQCh. 6 - Prob. 161RQCh. 6 - Prob. 162RQCh. 6 - Prob. 163RQCh. 6 - Prob. 164RQCh. 6 - Prob. 166RQCh. 6 - Prob. 167RQCh. 6 - Prob. 168RQCh. 6 - Prob. 169RQ
Knowledge Booster
Background pattern image
Mechanical Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Text book image
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Text book image
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Text book image
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Text book image
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Text book image
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
The Refrigeration Cycle Explained - The Four Major Components; Author: HVAC Know It All;https://www.youtube.com/watch?v=zfciSvOZDUY;License: Standard YouTube License, CC-BY