Concept explainers
The heat transfer with the surrounding that is needed to maintain the temperature and pressure of R-134a constant.
Explanation of Solution
Given:
The bottle internal volume
The initial mass of the refrigerant
The temperature of the refrigerant
The final mass of the refrigerant
Calculation:
At the initial state 1:
The rigid container consist of saturated mixture refrigerant at
Refer Table A-11, “Saturated refrigerant-134a-Temperature table”.
Obtain the following corresponding to the temperature of
The quality of the refrigerant at state 1 is expressed as follows.
The internal energy of the refrigerant at state 1 is expressed as follows.
At the final state (2):
When the valve is opened, the vapor refrigerant only allowed to escape and the temperature is kept constant.
The final temperature of the refrigerant is also
Refer Table A-12, “Saturated refrigerant-134a-Temperature table”.
Obtain the following corresponding to the temperature of
The quality of the refrigerant at state 2 is expressed as follows.
The internal energy of the refrigerant at state 2 is expressed as follows.
Write the equation of mass balance.
Here, the inlet mass is
The change in mass of the system for the control volume is expressed as,
Here, the subscripts 1 and 2 indicates the initial and final states of the system.
Consider the given rigid container as the control volume.
Initially the container is filled with liquid refrigerant and the valve is in closed position, further no other mass is allowed to enter the container. Hence, the inlet mass is neglected i.e.
Rewrite the Equation (I) as follows.
Write the formula for initial specific volume
Write the formula for final specific volume
Write the energy balance equation.
Here, the heat transfer is
The process is maintained at isothermal at the open condition of valve, there is no heat transfer while the mass leaves the container .i.e.
The Equation (V) reduced as follows.
Here, the temperature is kept constant until the final state and the vapor only exits the tank. Hence the exit enthalpy is expressed as follows.
Refer Table A-12, “Saturated refrigerant-134a-Temperature table”.
The exit enthalpy
Substitute
Thus, the heat transfer with the surrounding that is needed to maintain the temperature and pressure of R-134a constant is
Want to see more full solutions like this?
Chapter 6 Solutions
Fundamentals Of Thermal-fluid Sciences In Si Units
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY