Electricity for Refrigeration, Heating, and Air Conditioning (MindTap Course List)
10th Edition
ISBN: 9781337399128
Author: Russell E. Smith
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 6, Problem 5RQ
Draw the symbols for the following components.
- a. heating thermostat
- b. cooling thermostat
- c. pressure switch (opens on rise)
- d. thermal line break overload
- e. fuse
- f. magnetic overload
- g. crankcase heater
- h. three-pole contactor
- i. relay with one NO and one NC contact
- j. red signal light
- k. three-phase compressor motor
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Select the simple system from the following.
a.
Air conditioner
b.
Closed loop room heating system
c.
Speed control of Motor
d.
Lamp with on/off switch
FLUID POWER SYSTEMS
Name
Section 5-2: Line Diagrams-Signals,
Decisions, and Actions
In the following application, a temperature switch controls a heating contactor and a flow switch is used to
ensure there is enough air flow. If there is not enough air flow, an alarm is sounded. Complete the required
information.
1. List all the signal devices in the circuit.
2. List all the action devices in the circuit.
3. List the decision part of the circuit that automatically sounds the alarm if there is a problem.
4. When the heating element is on during normal operation, is the flow switch open or closed?
CIRCULATING
2
L1
FAN
TEMPERATURE
SWITCH
TR
HEATING
ELEMENTS
FLOW
SWITCH
-HOT AIR
PADDLE
AIR FILTER
NORMALLY CLOSED
FLOW SWITCH
65
ALARM
(SOUNDS IF NO FLOW FOR
15 SECONDS OR MORE)
Date
HEATING
CONTACTOR
TR
ON-DELAY
TIMER
SUPPLY AIR
COLD AIR
(3) TIME SET= 15 SEC
© 2014 American Technical Publishers, Inc.
All rights reserved
Chapter 6 Solutions
Electricity for Refrigeration, Heating, and Air Conditioning (MindTap Course List)
Ch. 6 - Why should an air-conditioning technician learn to...Ch. 6 - Briefly explain the layout of a schematic diagram.Ch. 6 - Most schematic diagrams are made up of _____. a....Ch. 6 - Schematic diagrams break the wiring of control...Ch. 6 - Draw the symbols for the following components. a....Ch. 6 - What is the name of an appliance that is used to...Ch. 6 - What is the position of the control switch if the...Ch. 6 - Prob. 8RQCh. 6 - True or False: The evaporator fan motor is...Ch. 6 - What electrical component initiates the defrost...
Ch. 6 - The thermostat of the commercial freezer in Figure...Ch. 6 - What is the purpose of the fan switch in Figure...Ch. 6 - If the temperature in the furnace schematic shown...Ch. 6 - What is the purpose of the transformer in Figure...Ch. 6 - True or False: The system in Figure 6.28 is using...Ch. 6 - The HP and LP switches are connected in __________...Ch. 6 - The contactor is controlled by __________. a. the...Ch. 6 - With the fan switch in the on position, the indoor...Ch. 6 - The compressor and condenser fan motor start...Ch. 6 - The compressor and condenser fan motor are...Ch. 6 - Prob. 21RQCh. 6 - Prob. 22RQCh. 6 - Explain why the lockout relay coil energizes...Ch. 6 - True or False: The first- and second-stage cooling...Ch. 6 - True or False: A two-stage cooling thermostat...Ch. 6 - What is the purpose of the defrost cycle of a heat...Ch. 6 - What two factors initiate the defrost mode in the...Ch. 6 - What type of thermostat is used with the heat pump...Ch. 6 - Explain the operation of the switchover valve and...Ch. 6 - The reversing-valve solenoid is energized on the...Ch. 6 - The defrost cycle of the heat pump schematic in...Ch. 6 - What is a pump-down system and why is it used in...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Select the proper choice(s) for each of the following statements: 1) To control single-acting cylinder we just need: double-acting cylinder we should use A2/2-way, 5/2-way, (C) 3/3-way, 3/4-way, 2) In DCV. (B) 3/2-way, 4/2-way, (D) 4/3-way, 3/2-way. mid poistion of DCV, we can move cylinder piston rod freely without resistance by hand. (A) working ports are exhausted, (C) working ports are pressurized, 3) In pneumatics we use A Compressor (B) Pump, DCV, while to control the 4) Quick exhaust valve is used to (A) increase the cylinder return speed. (C) meter-out the cylinder speed (B) all ports are closed. no one of these options. to obtain high pressure air. (C) Turbine, (D) pressure relief valve. (B) meter-in the cylinder speed, (D) increase the cylinder extending speed. 6) Meter-in of cylinder movement is used to control the Afluid that enters the hydraulic cylinder, (B) fluid that exits the hydraulic cylinder, (C) fluid that enters the DCV (D) fluid that exits the DCV. 5) One of the…arrow_forward_controls on/off of the motor, when the air compressor tank reaches the specified bar. O a. Electric Motor. O b. Auto drain. O C. Compressor. d. Pressure Switch.arrow_forward4. Describe two type of starting system principles and draw the basic starting circuitarrow_forward
- 23. Draw the following symbols: a. double acting, momentary contact push button. b. normally open pressure switch C. current transformer. d. Normally closed float switch. e. normally open limit switch. F. normally closed switch.arrow_forwardSelect the most accurate system from the following, O a. Lamp with on/off switch O b. Room heating system O c. Traffic light O d. Air conditionerarrow_forwardPlease answer it Asap and completely for an upvote. Thank you.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage LearningElectrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage Learning
- Automotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
Hydronics Step by Step; Author: Taco Comfort Solutions;https://www.youtube.com/watch?v=-XGNl9kppR8;License: Standard Youtube License