Electricity for Refrigeration, Heating, and Air Conditioning (MindTap Course List)
10th Edition
ISBN: 9781337399128
Author: Russell E. Smith
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 6, Problem 13RQ
If the temperature in the furnace schematic shown in Figure 6.25 were to increase to an unsafe condition, what electrical device would interrupt the power supply to the gas valve?
- a. fan switch
- b. heating thermostat
- c. limit switch
- d. all of the above
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Which of the following is most responsible
for providing or blocking heat to the
passenger compartment?
Select one:
a. The heater control valve
b. The water pump
c. The thermostat
d. The radiator cap
While calculating the pressure difference for stack effect for a building with
more openings in the higher part, the neutral pressure level:
Select one:
a.
O b.
O C.
d.
O
None of the options
Is higher than the mid-height of the building
Is lower than the mid-height of the building
Is at the mid-height of the building
If the thermostat contacts are closed the compressor and the condenser fan motor are not operating, and all the other loads are operating properly, which might be the problem?
A. A bad high pressure safety switch.
B. A bad low pressure switch
C. Both A. and B.
D. A bad thermostat
Chapter 6 Solutions
Electricity for Refrigeration, Heating, and Air Conditioning (MindTap Course List)
Ch. 6 - Why should an air-conditioning technician learn to...Ch. 6 - Briefly explain the layout of a schematic diagram.Ch. 6 - Most schematic diagrams are made up of _____. a....Ch. 6 - Schematic diagrams break the wiring of control...Ch. 6 - Draw the symbols for the following components. a....Ch. 6 - What is the name of an appliance that is used to...Ch. 6 - What is the position of the control switch if the...Ch. 6 - Prob. 8RQCh. 6 - True or False: The evaporator fan motor is...Ch. 6 - What electrical component initiates the defrost...
Ch. 6 - The thermostat of the commercial freezer in Figure...Ch. 6 - What is the purpose of the fan switch in Figure...Ch. 6 - If the temperature in the furnace schematic shown...Ch. 6 - What is the purpose of the transformer in Figure...Ch. 6 - True or False: The system in Figure 6.28 is using...Ch. 6 - The HP and LP switches are connected in __________...Ch. 6 - The contactor is controlled by __________. a. the...Ch. 6 - With the fan switch in the on position, the indoor...Ch. 6 - The compressor and condenser fan motor start...Ch. 6 - The compressor and condenser fan motor are...Ch. 6 - Prob. 21RQCh. 6 - Prob. 22RQCh. 6 - Explain why the lockout relay coil energizes...Ch. 6 - True or False: The first- and second-stage cooling...Ch. 6 - True or False: A two-stage cooling thermostat...Ch. 6 - What is the purpose of the defrost cycle of a heat...Ch. 6 - What two factors initiate the defrost mode in the...Ch. 6 - What type of thermostat is used with the heat pump...Ch. 6 - Explain the operation of the switchover valve and...Ch. 6 - The reversing-valve solenoid is energized on the...Ch. 6 - The defrost cycle of the heat pump schematic in...Ch. 6 - What is a pump-down system and why is it used in...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Which of the following would not increase the rate of heat transferred from a heater pipe? A. Insulating with materials whose thickness is below that of critical thickness for insulation. B. Blowing air over it C. Providing fins D. Placing the heater pipe within another whose thermal conductivity is smaller in number and 2 inches thickarrow_forwardto run d. both a and b 44. Ifa thermostatic expansion valve's thermal bulb came loose from the suction line at the outlet of the evaporator, whích of the following could result? The bulb pressure would increase and the c. thermostatic expansion valve would open. b. The superheat in the evaporator would decrease. a. Liquid refrigerant would flow back to the compressor. d. All of the above are correct. 45. If the thermal bulb assembly develops a leak, what will occur? All of the system's refrigerant will leak a. The valve will open to allow more c. refrigerant to flow. d. It will have no effect on system operation. out. b. The bulb pressure will reduce and the valve will close. 46. The purpose of an externally equalized thermostatic expansion valve is to compensate for excessive evaporator pressure drop b. allow system to equalize faster a. prevent the expansion valve from frosting up d. c. allow refrigerant to expand in the compressor 47. The primary function of an expansion device is…arrow_forwardDescribe the method a service technician should follow when measuring the current that normally travels through a heating anticipator.arrow_forward
- Which of the following components is NOT a type of ventilation system? Select one: a. Airconditioning Units b. Venting Skylight c. Boilers d. Exhaust Fansarrow_forwardQuestion1. If an air conditioning system has three independent zones, how many space thermostats will the system have? Question 2. A technician is traversing a duct and obtains the following 8 velocity: 500fpm, 400fpm, 375fpm,625fpm,275fpm,360fpm,450fpm,and 575fpm. What is the velocity value that can be used for the system calculations?arrow_forwardWhat is the primary purpose of a thermostat jiggle valve? Select one: a. To act as a bypass for coolant b. To relieve water pump pressure under load c. To ensure coolant flows the correct direction d. To aid in bleeding air from the systemarrow_forward
- 2. Design a thermostatarrow_forwardIf the compressor and condenser fan motor will not operate but the indoor fan motor is operating, what would be the probable cause of the malfunction? a. Bad contactor coil b. Bad thermostat c. Bad condenser fan motor d. Bad compressorarrow_forwardA pressure switch is to be installed on a system with pressures that can range from 1500 PSI to 1800 PSI. What type of pressure switch should be used?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage LearningUnderstanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
The Refrigeration Cycle Explained - The Four Major Components; Author: HVAC Know It All;https://www.youtube.com/watch?v=zfciSvOZDUY;License: Standard YouTube License, CC-BY