The maximum flow rate of standard shower heads is about 3.5 gpm (13.3 L/min) and can be reduced to 2.75 gpm (10.5 L/min) by switching to low-flow shower heads that are equipped with flow controllers. Consider a family of four, with each person taking a 5-min shower every morning. City water at 15°C is heated to 55°C in an electric water heater and tempered to 42°C by cold water at the T-elbow of the shower before being routed to the shower heads. Assuming a constant specific heat of 4.18 kJ/kg·°C for water, determine (a) the ratio of the flow rates of the hot and cold water as they enter the T-elbow and (b) the amount of electricity that will be saved per year, in kWh, by replacing the standard shower heads with the low-flow ones.
(a)
The ratio of flow rates of hot and cold water as they enter the T-elbow.
Answer to Problem 168RP
The ratio of flow rates of hot and cold water as they enter the T-elbow is
Explanation of Solution
Here, the two streams (comparatively hot and cold) of fluids are mixed in a rigid mixing chamber and operates at steady state. Hence, the inlet and exit mass flow rates are equal.
Write the energy rate balance equation for two inlet and one outlet system.
Here, the rate of heat transfer is
The system is at steady state. Hence, the rate of change in net energy of the system becomes zero.
Neglect the heat transfer, work transfer, kinetic and potential energies.
The Equation (II) reduced as follows.
Substitute
The change in enthalpy is expressed as follow.
Here, the specific heat is
Substitute
Conclusion:
Substitute
Thus, the ratio of flow rates of hot and cold water as they enter the T-elbow is
(b)
The amount of electricity that will be saved per year, in
Answer to Problem 168RP
The amount of electricity that will be saved per year, in
Explanation of Solution
Here, the volume flow rate in the shower heads is lowered by installing low-flow shower heads equipped with flow controllers. This reduces the volume flow rate of water that is consumed per person.
The volume flow rated saved is expressed as follows,
The total volume flow rate saved by the family per year is expressed as follows.
Write the formula for total mass of water saved per year.
Write the formula for energy saved due to the installation of lower shower heads.
Refer Table A-3 (a), “Properties of common liquids, solids, and foods”.
The specific heat at constant pressure
The density of the water
Conclusion:
Substitute
Substitute
Substitute
Thus, the amount of electricity that will be saved per year, in
Want to see more full solutions like this?
Chapter 5 Solutions
THERMODYNAMICS(SI UNITS,INTL.ED)EBOOK>I
- Ammonia refrigerant circulates in a refrigeration system with one compressor serving two evaporators where one evaporator carries a load of 35 kW at 10°C and the other a load of 70 kW at -5°C. A back pressure valve reduces the pressure in the 10°C evaporator to that of the -5°C evaporator. The condensing temperature is 37°C. Calculate the mass of the refrigerant in kg/s. (Use h₂ = h1 + 203.7586 kJ/kg)arrow_forwardTwo boilers are operating steadily on 91,000 kg of coal contained in a bunker. One boiler is producing 1,591 kg of steam per hour at 1.2 factor of evaporator and an efficiency of 65% and another boiler produced 1,364 kg of steam per hour at 1.15 factor of evaporation and an efficiency of 60%. How many hours will the coal in the bunker run the boilers if the heating value of coal is 7,590 kCal/kg? 230.8 O 118.2 O 94.54 O 184.6 O 147.7arrow_forwardWhat is an adiabatic process?arrow_forward
- The Refrigerating Effect of 94 tons of refrigeration is 127.75 kJ/kg. Determine the mass flow rate of the refrigerant.arrow_forwardAn electric windshield defroster is used to remove 0.25-in of ice from a windshield. The properties of the ice are Tsat = 328F, uif = hif = 144 Btu/lbm, and v = 0.01602 ft3/lbm. Determine the electrical energy required per square foot of windshield surface area to melt this ice and remove it as liquid water at 328F. What is the minimum temperature at which the defroster may be operated? Assume that no heat is transferred from the defroster or ice to the surroundings.arrow_forward14- 300 kPa and 20 ºC water is heated in a mixing room with 300kPa pressure and 300 ºC steam. If the mass flow of cold water is 1.8 kg/h and the temperature of the flow is 60 ºC, what is the mass flow of the superheated steam? A- 1,457 kg/sB- 1,987 kg/sC- 10,635 kg/sD- 0,107 kg/s E- 2,569 kg/s (Note: This Turkish I'm using translate) orginal; 300 kPa ve 20 ºC sıcaklıktaki su bir karışma odasında 300kPa basınç ve 300 ºC sıcaklıktaki buharla ısıtılmaktadır. Soğuk suyun kütle debisi 1.8 kg/s , çıkan akışın sıcaklığı 60 ºC ise kızgın buharın kütle debisi nedir?arrow_forward
- Need solution to question 6 only within 20 minutes (answer of question 5 is 6.82m/s)arrow_forwardAn air refrigeration system having pressure ratio of 5 takes air at 0°C and 1 atm. It is compressed and then cooled to 19°C. A pressure drop of 5 kPa is measured in both cooler and refrigerator. If the efficiency of the compressor is 95% and that of the expander is 75%, determine the refrigeration capacity of the system TR, and the COP of the system if the flow of air is 7.5 kg/min. Assume compression and expansion processes to be isentropic.arrow_forwardSolve the following problems: Note: Draw the p-h diagram completely labeling the respective refrigerant conditions (pressures and temperatures) and define the properties of refrigerant (enthalpies and specific volume) needed to solve the respective problems. In an ammonia refrigeration system, the capacity is (1) 210 kW at a temperature of-20°C. The vapor from the evaporator is pumped by one compressor to the condensing pressure of 1431 kPa. Later, the system was revised to a two-stage compression operating on the cycle shown below with intercooling but no removal of flash at 555 kPa. (а) Calculate the power required by the single compressor in the original system. (b) Calculate the total power required by the two compressors in the revised system. Condenser 1431kPa High-stage compressor Intercooler 555kPa Evaporator 2í0kW -20°C Low-stage compresaorarrow_forward
- The approach and efficiency of cooling tower are 10 oC and 65 %, respectively. If the temperature of water leaving the tower is 27 oC, determine the temperature of water entering the tower.arrow_forwardThe maximum efficiency of a heat engine works between 660 K and 323 K isarrow_forwardA six-cylinder refrigerant 22 compressor operating at 29 r/s indicate a refrigerating capacity of 96.4 kW and a power requirement of 28.9 kW at an evaporating temperature of 5°C and condensing temperature of 50°C. The performance data are based on 3°C liquid sub-cooling and 8°C superheating of the suction gas entering the compressor. The cylinder bore is 67 mm and the piston stroke is 57 mm. Compute (a) the clearance volumetric efficiency if the clearance volume is 4.8 percent, (b) the actual volumetric efficiency, and (c) the compression efficiency.arrow_forward
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning