Textbook Question
Chapter 40, Problem 14RQ
The compressor amperage of a 3-ton system operating on 230 V is approximately -A.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
17) What is the approximate Peritectic Temperature for the system?
46. Question
The capacity of a Freon 12 refrigeration system with a direct expansion evaporator
installed is 8.50 tonnes of refrigeration. Assuming that the refrigeration system is
operating under standard conditions of -15°C evaporation & 30"C condensation
the power to drive the compressor is 0.922 kw per tonne of refrigeration with a
system efficiency of 85%. Determine the compressor displacement.
10. Name two things in the design of a reciprocating com
pressor that control the efficiency of the compressor.
A.
В.
Chapter 40 Solutions
Refrigeration and Air Conditioning Technology (MindTap Course List)
Ch. 40 - The standard design conditions for...Ch. 40 - The typical temperature relationship between a...Ch. 40 - The evaporator will normally operate at a(n)...Ch. 40 - A typical temperature relationship between a...Ch. 40 - How is condenser high efficiency obtained?Ch. 40 - High-efficiency air-conditioning systems may use...Ch. 40 - What does the head pressure do If the suction...Ch. 40 - What will cause the suction pressure to rise?Ch. 40 - The evaporator design temperature may in some...Ch. 40 - The seasonal energy efficiency ratio (SEER)...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A fan running at 2000 rpm delivers 16,000 cfm against 3 in. static pressure, thereby consuming 15BHp. If the rpm is increased to 2300 rpm so that the rpm ratio is 1.5:1. What is the new cfm?arrow_forwardThe compressor work of an air compressor is 120kw. If piston displacement is 18m3/min, determine the mean effective pressure. A. 400kpa B. 300kpa C. 500kpa D. 600kpaarrow_forwardFor the purpose of acting as an air-cooled water chiller, an ammonia refrigerant vapor compression system is deployed. It is functioning with an evaporator temperature of 0 degrees Celsius and a condenser temperature of 40 degrees Celsius. The refrigeration produced by the system is equal to 15 tons.Find out: a. The temperature of the discharge and the mass flow rate of the refrigerant that is being circulated.b. The piston displacement that can be considered theoretical for the compressor.c. The work that can be done by the theoretical compressor.d. The heat that is not allowed to escape through the condenser.e. The Carnot coefficient of performance and the actual COP of the cycle.f. The volume of air that is supplied in the condenser if the air comes in at 30 degrees Celsius and exits at 34 degrees Celsius.g. The LMTD and AMTD of the condenser h. The water flow rate of the chiller assuming that the water enters the evaporator at 10 degrees Celsius and exits at 5 degrees Celsiusi. The…arrow_forward
- By using equations,show and explain why power required by compressor is higher when temperature at induction is higher than the ambient.arrow_forward6. A two stage air compressor has an intercooler pressure of 300kpa. If the suction pressure is 100kpa, what is the discharge pressure? a. 130.57psi b. 130.57kPa c. 600psi d. 600kPa Please answer this immediately. Thank you!arrow_forwardQUESTION 20 A single-stage, single-acting air compressor with runs at speed 600 rpm. It has a polytropic index of 1.26. The induced volume flow rate is 7.2 cubic meters per min and the air must be delivered at a pressure of 674 kPa. The free air conditions are 101.3 kPa and 15 degrees Celsius. The clearance volume is 6% of the stroke volume and the stroke/bore ratio is 1.6/1. Calculate the delivery air. Hint answer usaully in C and no need for °C.arrow_forward
- the highest pressure of water in the power plant cycle is located a. after the boiler b. at the turbine exit c. at the exit of condenser d. at the inlet of turbinearrow_forward1. Pressure gauge the hydraulic cycle in figure -consist of:7 5 6 X LB ww M 3 Feed direction & tank O accumalator O intensifier O 3 way 2 position control valve Oarrow_forwardIn all liquid refrigerant lines, the pressure at the bottom of a vertical rise isgreater than the pressure at the top of the rise. For R-134a, the pressure isabout 0.5144 lb/sq in or less for every vertical foot of pipe that is used. Thevertical rise between this condenser and evaporator is 7.5 feet. How muchless is the pressure at the top of the rise than at the bottom?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Power Plant Explained | Working Principles; Author: RealPars;https://www.youtube.com/watch?v=HGVDu1z5YQ8;License: Standard YouTube License, CC-BY