The standard design conditions for air-conditioning systems established by the Air-Conditioning, Heating and Refrigeration Institute (AHRI) are outside temperature _____°F, inside temperature ______°F, with a humidityof____%.
The standard design conditions established by AHRI for air conditioning system.
Answer to Problem 1RQ
The standard design conditions established by AHRI for air conditioning system are
Explanation of Solution
All the air conditioning equipments are designed to operate on its rated capacity and efficiency. The ratings are standardized by Air conditioning, heating and refrigeration institute (AHRI).
Air conditioning, heating and refrigeration institute established the standard design conditions of
Conclusion:
Thus, standard design conditions established by AHRI for air conditioning system are
Want to see more full solutions like this?
Chapter 40 Solutions
Refrigeration and Air Conditioning Technology (MindTap Course List)
- A summer air-conditioning shown below is required to maintain a certain room at specified conditions. The layout of the system is indicated on the next page and the specifications are listed below.System specifications:Required room temperature: 23⁰C, 50% Relative humidityAtmospheric pressure: 101 kPaOutside air conditions: 30⁰C, 80% Relative humidity Sensible heat gain: 5 kWLatent heat gain: 4 kWTemperature rise across fan: 1.5⁰CTemperature of air leaving cooler: 12⁰CTemperature of air entering room: 18⁰CApparatus dew point of cooler: 7⁰Carrow_forwardEvaporation cooling in cooling towers heat transfer analysis.arrow_forwardIn many temperature control applications, __________ is the controlled variable.arrow_forward
- The effect of _____ wind speeds generally increase with height above the ground.arrow_forwardExplain why the outside air damper is typically nevercompletely closed, even when the outside air conditionsare not adequate to provide free-cooling.arrow_forwardThe design boiling point for most evaporator coils in residential air-conditioning is __________ °F.arrow_forward
- The following instruments are used to measure the temperature: Select one: O a. Bi-metallic Thermometer, Vapor Pressure Thermometer, Vacuum Insulated flask O b. Amplifier, Red Spirit in Glass Thermometer, Bi-metallic Thermometer O c. Platinum Resistance Thermometer, Thermistors, Thermocouples, Heater Plate O d. Red Spirit in Glass Thermometer, Bi-metallic Thermometer, Vapor Pressure Thermometerarrow_forwardA domestic refrigerator sits in a kitchen, switched on, with the refrigerator door wide open. The kitchen itself is well insulated and it can be assumed no heat can escape or enter the kitchen from the outside. Which of the following is the most accurate statement. a. The temperature in the kitchen will go down very slightly. O b. The temperature in the kitchen could go up or down, depending on the Coefficient of Performance (COP) of the refrigerator. O c. The temperature in the kitchen could go up or down depending on the mechanical efficiency of the compressor. O d. The temperature in the kitchen will stay the same. O e. The temperature in the kitchen will go up very slightly.arrow_forwardneed help. air conditioningarrow_forward
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning