Summary Introduction
To answer:
To interpret the function of immersion oil to a novice
Introduction:
The resolving power of a microscope was increased by using the immersion oil. It was attained by immersing the objective lens and the slide containing the sample in transparent oil. The immersion oil increases the numerical aperture of the objective lens as it has a high refractive index. Placing of immersion oil helps the light to travel at a uniform speed and it does not refract. Cedar wood oil is commonly used as immersion oil.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A novice microbiology student incorrectly explains that immersion oil increases the magnification of his microscope. What is the function of immersion oil?
For a laboratory exercise of basic techniques in microbiology: Gram stain and Microscopy.
What are the sources of error in performing Gram staining?
Please discuss why staining is important in visualizing microbes under the microscope.
What different types of staining methods can be used?
Chapter 4 Solutions
Microbiology with Diseases by Body System (4th Edition)
Ch. 4 - Prob. 1TMWCh. 4 - Why is a Gram-negative bacterium colorless but a...Ch. 4 - Why didnt Linnaeus create taxonomic groups for...Ch. 4 - Necrotizing Fasciitis Fever, chills, nausea,...Ch. 4 - Why is magnification high and color absent in an...Ch. 4 - Prob. 1MCCh. 4 - Prob. 2MCCh. 4 - Prob. 3MCCh. 4 - Curved glass lenses _________ light. a. refract b....Ch. 4 - Prob. 5MC
Ch. 4 - Prob. 6MCCh. 4 - Prob. 7MCCh. 4 - Prob. 8MCCh. 4 - Prob. 9MCCh. 4 - In the binomial system at nomenclature, which term...Ch. 4 - Prob. 1FIBCh. 4 - Prob. 2FIBCh. 4 - Prob. 3FIBCh. 4 - Fill in the Blanks 4. ___________ refers to...Ch. 4 - Fill in the Blanks 5. Cationic chromophores such...Ch. 4 - Prob. 1VICh. 4 - Label the microscope.Ch. 4 - Prob. 1SACh. 4 - Critique the following definition of magnification...Ch. 4 - Prob. 3SACh. 4 - Put the following substances in the order they are...Ch. 4 - Prob. 5SACh. 4 - Prob. 6SACh. 4 - Prob. 7SACh. 4 - Prob. 8SACh. 4 - Miki came home from microbiology lab with green...Ch. 4 - Why is the definition of species as successfully...Ch. 4 - With the exception of the discovery of new...Ch. 4 - Prob. 4CTCh. 4 - Prob. 5CTCh. 4 - In what ways are the Gram stain and the acid-fast...Ch. 4 - Prob. 7CTCh. 4 - Prob. 8CTCh. 4 - Why is the genus name Coccus placed within...Ch. 4 - A clinician obtains a specimen of urine from a...Ch. 4 - Using the following terms, fill in the following...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, biology and related others by exploring similar questions and additional content below.Similar questions
- a)What is the condenser lens on a compound microscope, and how can it affect your view of your specimen? b)Calculate the total magnification when looking through the 40X lens on the compound microscope. c) Describe the process to get a specimen into view using the 40X objective starting from the point after you have plugged in your scope and cleaned the objectives and slide.arrow_forwardExplain how to correctly use the microscope using oil immersion.arrow_forwardWhy would specimens viewed with a compound microscope be thin and/or chemically cleared?arrow_forward
- (a) Which would be easier to prepare bacterial smear from, liquid or solid culture? Why? (b) Aside from bacteria, can gram staining be used with microbes such as fungi? Explain your answer.arrow_forwardWhy is it sometimes difficult to attain both good resolution and good contrast at the same time for a sample that is being observed on the microscope stage? Please give a thorough response,arrow_forwardHow will the following affect resolution during microscopy? I) Closing or opening the diaphragm II) Raising or lowering the condenser III) Increasing or reducing the light intensityarrow_forward
- How can colony morphology be used in the identification of bacterial species? What are the environmental factors that affect the growth of bacteria? What is agar (or agar-agar)? Is this different from nutrient agar? Why? How is xylol used to clean the lens of a microscope? What may happen if xylol is constantly used for this purpose? For what purpose would you adjust each of the following microscope components during a microscopy exercise? iris diaphragm coarse adjustment knob fine adjustment knob condenser mechanical stage controlarrow_forwardBefore viewing a specimen of pigmented bacteria on a slide under the light microscope, which of the following usually needs to happen (and why)? Staining (to increase magnification). Heat, radiation or antimicrobial chemical treatment (to kill the bacteria for safe observation). Add immersion oil (to increase resolution). Add a cover slip (to reduce contamination). The viewing chamber needs to be flushed of air (to create a vacuum).arrow_forwarda. What can you observe in viewing your stained bacterial slide under the microscope if you fixed a lot of bacterial colonies in your slide during smear preparation? b. What can you observe in viewing your stained bacterial slide under the microscope if you heat fixed your slide in a much longer exposure to heat?arrow_forward
- The above photograph (IMAGE ATTACHED) of a cheek smear was obtained using the high-power objective of a compound microscope. What is the size of the circled cheek cell in millimeters AND nanometers?arrow_forwardWhy is oil immersion necessary to see bacteria in the laboratory?arrow_forwardWhat type of microscope is suitable for observing thin and translucent specimens?arrow_forward