Understanding Motor Controls
4th Edition
ISBN: 9781337798686
Author: Stephen L. Herman
Publisher: Delmar Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 37, Problem 9RQ
To determine
The size of the conductor, overload size, circuit breaker size, NEMA and IEC starter sizes, the upper and lower range of the starting current for the motor.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
The working current has a power of 100 kW and a power factor of 0.50. After a capacitor of 75 KVAR is installed, what does the
power factor become?
A 0.84
B 0.71
C 0.63
D 0.78
E 0.92
The following data were obtained on a 50 kVA 2400/120 V transformer:
Open circuit test, instruments on low voltage side:
Waltmeter reading = 396 Watts
Ammeter reading = 9.65 amperes
Voltmeter reading = 120 Volts
Short circuit test, instruments on high voltage side:
Waltmeter reading = 810 Watts
Ammeter reading = 20.8 amperes
Voltmeter reading = 92 Volts
Find the efficiency when rated kVA is delivered to a load having a power
factor of 0.8 lagging.The following data were obtained on a 50 kVA 2400/120 V transformer :
Open circuit test, instruments on low voltage side:
Waltmeter reading = 396 Watts
Ammeter reading = 9.65 amperes
Voltmeter reading = 120 Volts
Short circuit test, instruments on high voltage side:
Waltmeter reading = 810 Watts
Ammeter reading = 20.8 amperes
Voltmeter reading = 92 Volts
Find the efficiency when rated kVA is delivered to a load having a power
factor of 0.8 lagging.
In a given DC motor, the output power is 20 HP, and the copper losses are 1.1 KW. If the motor is operating at 87 % efficiency, find the converted power and the rotational losses. Select one:
a. Pconv = 16.05 KW and Prot = 1.13 KW
b. Pconv = 17.15 KW and Prot = 3.11 KW
c. Pconv = 14.92 KW and Prot = 1.35 KW
d. None
Chapter 37 Solutions
Understanding Motor Controls
Knowledge Booster
Similar questions
- A 10 kVA transformer has a primary voltage rating of 240 volts and a secondary voltage rating of 480 volts. The transformer is connected to a circuit protected by a 100 ampere circuit breaker. The secondary is protected by a 25-ampere fuse. Does the primary require separate overcurrent protection?arrow_forwardA 480-volt three-phase load is rated at 34.5 kVA. It is to be supplied with variable three-phase voltage. Because the load is continuous, the transformers ratings are to be increased by 1.25% of the rated load. Three variable autotransformers are used to supply this load. Refer to Table 4-2 and determine the standard size of each transformer that should be used to make this connection.arrow_forwardIf dual-element time delay fuses are to be used as the short circuit protective device, what size fuses should be used to protect the circuit in question #12? Five 5 HP, three-phase motors with NEMA code B are connected to a 240-volt line. The conductors are copper with type THWN insulation. What size conductor should be used to supply all of these motors?arrow_forward
- Two transformers rated at 100 kVA each are connected in an open-delta connection. What is the total output power that can be supplied by this bank?arrow_forwardwhat is the smallest gage size copper wire that will limit the conductor voltage drop to 5v when 120 vac is supplied to a 6-A loadarrow_forwardPlease answer ASAP.arrow_forward
- Find the value of the currents I1 and 12. 100 ohm 5V 5V 100 ohm 12 O a. 1=-0.3A, 12=-0.1A O b. 11=0.3A, 12=0.1A Oc. 11=0.05A, 12=0.1A O d. 11=0.1A, 12=0.2Aarrow_forwardThe arc length voltage characteristic of a DC arc is given by the equation V=24+4L where 'V' is the arc voltage in volts and L' is the length in mm. The static volt-ampere characteristic of the power source is approximated by a straight line with no load voltage of 80V and the short circuit current of 600A. Then the optimum arc length is (mm).arrow_forwardName three factors that determine the amount of induced voltage.arrow_forward
- In the experiment No.4, the core loss component current is given by_ Ic Sinôo lo Sindo lc Cos&o lo Cosoarrow_forwardQuestion 4 A 228 V/ 111 V single-phase transformer has a core loss of 110 W and the no-load current is 0.7 A. The no load power factor is Not yet answered Marked out of O 0.99 1.00 O 1.42 P Flag question O 0.48 O 0.69 Question 5 A 2 kV / 229 V transformer has the secondary turns of 47. The number of Primary turns of a transformer is given by, Not yet answered 63.83 Marked out of 410.48 1.00 O 615.72 P Flag question O 5381.50 Question 6 For the given power transfer, a delta system is associated with larger line currents and a star system is associated with a larger line voltage. Not yet answered Select one: Marked out of O True 1.00 P Flag question O Falsearrow_forwardA balanced star-connected load of (8 + j6) Q per phase is connected to a Balanced 3- phase 400-V supply. Find the line current, power factor, powerarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningElectrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning