Textbook Question
Chapter 31, Problem 7R
When selecting cables for a structured wiring system or computer hookups, the best choice is to select a cable that has
- a. untwisted pairs of conductors.
- b. twisted pairs of conductors.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
With respect to conductor insulation, describe the following location ratings: a. Dry b. Damp c. Wet
15. Which of the following conductors in a typical separable connection plug and receptacle has a firstmake, last-break feature?A. The neutral grounded conductorB. The equipment grounding conductorC. A center wye conductorD. The grounded delta conductor
Explain the concept of cable bending radius and why it is critical for cable installations. Provide examples of situations where this becomes crucial.
Chapter 31 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- D.1-. Which of the following names is commonly used for armored cable on commercial and industrial jobsites?A. RomexB. BXC. ECGD. MCD.2. Which of the following is the most common type of conductor termination used in commercial andindustrial wiring applications?A. A pressure connectionB. A wire nutC. A wire spliceD. A crimped connection D.3. Which of the following terms correctly describes a ventilated metal enclosure that supports powerdistribution conductors of up to 8000 A and 69 kV, and that allows for proper phase arrangement of theconductors?A. A trolley busB. A channel racewayC. A cablebusD. A feeder busarrow_forwardSingle core cable design for 25 kV. The radius of conductor is 0.5 cm. The insulation material consists of two layers. The thickness of each layer is 2 cm. The voltage of first and second layers are 20 kV, 5 kV respectively. The minimum Electric stress of the cable is *arrow_forwardc.1. Which of the following is one of the three essential functions of an equipment grounding conductor?A. Provide an arc-fault current pathB. Establish groundingC. Establish bondingD. Ensure the system is groundedc.2. What's another name for the three-point method of Earth resistance testing?A. Fall-of-potentialB. Line surgeC. Spatial shieldingD. Leakage current c.3. If the National Electrical Code provides a requirement to ground equipment, it generally implies thatthere will be a direct connection to the Earth of a connection through a/anA. grounding electrode conductor.B. equipment grounding conductor.C. equipotential bonding conductor.D. bonding conductor.arrow_forward
- A set of conductors is used to supply residential unit with a total load current of 60 A at a single-phase supply voltage of 230 V. What would be the minimum size of the conductor to be used to achieve at least 5% voltage drop? The total conductor length is 300 ft. ..arrow_forwardWhat are the colors of the conductors in nonmetallic-sheathed cable for a. 2-wire cable? _______________, _______________ b. 3-wire cable? _______________, _______________, _______________arrow_forwardWhat is the super tension cable and application,ratingarrow_forward
- 9. Which grounding method is typically required of higher-voltage systems? A. Grounding through inductorsB. Grounding through a low amount of resistanceC. Grounding through a high-impedance device D. Grounding through surge arresters 10. Which term relates to the conductors connected to the output side of a separately derived system? A. Neutral conductorB. Transformer secondary conductorC. System conductor D. Derived phased conductor 11. If there's no service disconnect at a remotely supplied building, then the grounding electrode conductor and the equipment grounding conductor can be bonded together at a A. junction box.B. structural steel location. C. grounding electrode rod. D. water line. 12. In a DC system, the bonding jumper between the negative of the supply and ground is normally made at the source or at the A. first disconnecting means. B. first device on the supply. C. end of the DC line.D. entrance to the building. 13. Which of the following is a common raceway…arrow_forwardDefine. What happens when you use cables longer than the prescribed length in a network?.arrow_forward1. The choice of conductor material will depend upon the and .......... 2. copper conductor used in the ......... form as standard ****** conductor. 3. We can used the Galvanized steel conductor for ........ or for 4. The wooden poles used in rural areas because it is 5. The holes in RCC used to and........ 6. Porcelain used as a good insulator and it mixture of ... ……...... and 7. Strain insulator used when there is a ......... or... 8. Because the shunt capacitor the ....... is not same through the dises and the efficiency will ......... 9. In Stormy weather, the ...... that make corona occurs at much less voltage compared to the fair weather. 10. String insulator with 4 units, 33.33% on the bottom most one. The string efficiency is ........ 11......... is the type of insulator used for holding the HV overhead conductor on the straight running poles. 12.......... possess no free-charge carriers and thus are non- conductive. 13. Corona accompanied by ....... .....arrow_forward
- A DC is supplied through a solid conductor cable. The fault in the cable can be determined by using Murray Loop Test. The healthy cable has the insulation resistance of 1 kilo Ohms per meter. No fault occurred till the first 10 km. The core of healthy cable has the circumference of 7.86cm. If the resistivity of insulation is 900 G Ohm-mm, what is the diameter of the cable.arrow_forwardb. traveler (ti)*) D. Several factors or conditions can cause conductors to overheat, but often overlooked is the possibility A a. induction heating b. ambient temperature C. the size of conductors d. groundingarrow_forward3. The three bus-bar conductors in an outdoor sub-station are supplied by units ofpost insulators. Each unit consists of a stack of 3-pin insulators fixed one on the top of the other. The voltage across the lowest insulator is 8-45 kV and that across the next is 7-25 kV. Find the bus-bar voltage of the station. [38-8 kV]arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTPower System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
Types of House Wiring - Types of Electrical Wiring - Electrical Wiring; Author: Learning Engineering;https://www.youtube.com/watch?v=A5P-buWX-dA;License: Standard Youtube License