EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN: 9781337516549
Author: Simmons
Publisher: CENGAGE LEARNING - CONSIGNMENT
expand_more
expand_more
format_list_bulleted
Question
Chapter 31, Problem 4R
To determine
Choose the correct option among the given choices to find “category-rated” cables that are most recommended to be used in wiring back to the main “service-center” from various outlets in the interconnection of computers.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
[Fill-in-the-blank] in dwelling units shall supply only loads within that dwelling unit or no loads associated only with that dwelling unit.
Select one:
a. None of these
b. Ground-fault protection
c. Service-entrance conductors
d. Branch circuits
5
12. Which of the following statements about ground faults is true?A. They can happen if a conductive tool is dropped in an energized equipment's electrical enclosure.B. They usually occur between any grounded circuit conductor and the equipment grounding conductor.C. They can't result from human error.D. They're often normal and typically intentional.
Chapter 31 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- c.1. Which of the following is one of the three essential functions of an equipment grounding conductor?A. Provide an arc-fault current pathB. Establish groundingC. Establish bondingD. Ensure the system is groundedc.2. What's another name for the three-point method of Earth resistance testing?A. Fall-of-potentialB. Line surgeC. Spatial shieldingD. Leakage current c.3. If the National Electrical Code provides a requirement to ground equipment, it generally implies thatthere will be a direct connection to the Earth of a connection through a/anA. grounding electrode conductor.B. equipment grounding conductor.C. equipotential bonding conductor.D. bonding conductor.arrow_forward15. What does a grounding symbol on a construction drawing convey?A. A single ground rodB. A grounding electrode systemC. A ground-fault current pathD. An equipment grounding conductorarrow_forward14. How many separate equipment grounding paths are required for branch circuits serving patient care spaces? A. One B. Two C. Four D. Threearrow_forward
- 19. What size copper bonding jumper must be used in an AC electrical system that has 500 kcmil copper phase conductors? A. 4/0 B. 1/0 C. 2/0 D. 3/0 20. A neutral disconnect link is usually in the form of a _______ in larger service equipment. A. screwB. wireC. clamp D. busbararrow_forward4.a. An intersystem bonding termination will typically be used as a ground junction for a/anA. patient care area.B. communications system installation.C. fire protection system.D. information technology room.4.b. The supply systems for sensitive electronic equipment are _______ systems.A. four-wire, three-phaseB. three-wire, single-phaseC. three-wire, three-phaseD. four-wire, single-phasearrow_forwardEquipment Grounding 10. Which of the following statements about ground faults is true?A. They usually occur between any grounded circuit conductor and the equipment grounding conductor. B. They're often normal and typically intentional.C. They can't result from human error.D. They can happen if a conductive tool is dropped in an energized equipment's electrical enclosure.arrow_forward
- Four No. 12 and four No. 10 conductors are to be installed in a EMT conduit 600 V jacketed. What size EMT conduit is required if a. The conductors are Type T90 Nylon? b. The conductors are Type RW90?arrow_forwardHow the required number of branch circuits can be determined?arrow_forward9. Which grounding method is typically required of higher-voltage systems? A. Grounding through inductorsB. Grounding through a low amount of resistanceC. Grounding through a high-impedance device D. Grounding through surge arresters 10. Which term relates to the conductors connected to the output side of a separately derived system? A. Neutral conductorB. Transformer secondary conductorC. System conductor D. Derived phased conductor 11. If there's no service disconnect at a remotely supplied building, then the grounding electrode conductor and the equipment grounding conductor can be bonded together at a A. junction box.B. structural steel location. C. grounding electrode rod. D. water line. 12. In a DC system, the bonding jumper between the negative of the supply and ground is normally made at the source or at the A. first disconnecting means. B. first device on the supply. C. end of the DC line.D. entrance to the building. 13. Which of the following is a common raceway…arrow_forward
- Briefly explain conduit wiring as applied to domestic or industrial wiring and list two (2) advantages of conduit wiring.arrow_forward8.a. A _______ conductor does not carry current during normal operation.A. neutralB. groundingC. phaseD. grounded8.b. "The complete path of an electric current" describes an electric(al)A. fault.B. circuit.C. source.D. component.arrow_forward11. Specific rules apply for the installation of _______, but no identification requirements for them exists.A. grounding electrode conductorsB. grounding electrodes.C. main bonding jumpers.D. equipment grounding conductors.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Types of Protective Relays and Design Requirements, Part 1a.; Author: GeneralPAC: Power System Tutorials;https://www.youtube.com/watch?v=JYil4T5VSDM;License: Standard Youtube License