Exposure to high concentrations of gaseous ammonia can cause lung damage. To prevent gaseous ammonia from leaking out, ammonia is transported in its liquid state page 232 through a pipe ( k = 25 W/m .K, D i =25 cm, D o =4 cm and L= 10 m) . and Since liquid ammonia has a normal boiling point of -33.3°C, the pipe needs to be properly insulated to prevent the surrounding heat from causing the ammonia to boil. The pipe is situated in a laboratory, where the average ambient air temperature is 20°C. The convection heat transfer coefficients of the liquid anunonia and the ambient air are 100 Wm2K and 20 Vin2K. respectively. Determine the insulation thickness for the pipe using a material with k = 0 .75W/m 2 .K, to keep the liquid ammonia flowing at an average temperature of -35°C, while maintaining the insulated pipe outer surface temperature at 10°C.
Exposure to high concentrations of gaseous ammonia can cause lung damage. To prevent gaseous ammonia from leaking out, ammonia is transported in its liquid state page 232 through a pipe ( k = 25 W/m .K, D i =25 cm, D o =4 cm and L= 10 m) . and Since liquid ammonia has a normal boiling point of -33.3°C, the pipe needs to be properly insulated to prevent the surrounding heat from causing the ammonia to boil. The pipe is situated in a laboratory, where the average ambient air temperature is 20°C. The convection heat transfer coefficients of the liquid anunonia and the ambient air are 100 Wm2K and 20 Vin2K. respectively. Determine the insulation thickness for the pipe using a material with k = 0 .75W/m 2 .K, to keep the liquid ammonia flowing at an average temperature of -35°C, while maintaining the insulated pipe outer surface temperature at 10°C.
Solution Summary: The author analyzes the thermal resistances of different layers by solving for the insulation thermal conductivity yields kins = 0.75 W/m-K.
Exposure to high concentrations of gaseous ammonia can cause lung damage. To prevent gaseous ammonia from leaking out, ammonia is transported in its liquid state page 232 through a pipe
(
k
=
25
W/m
.K,
D
i
=25 cm, D
o
=4 cm and L= 10 m)
.
and Since liquid ammonia has a normal boiling point of -33.3°C, the pipe needs to be properly insulated to prevent the surrounding heat from causing the ammonia to boil. The pipe is situated in a laboratory, where the average ambient air temperature is 20°C. The convection heat transfer coefficients of the liquid anunonia and the ambient air are 100 Wm2K and 20 Vin2K. respectively. Determine the insulation thickness for the pipe using a material with
k = 0
.75W/m
2
.K,
to keep the liquid ammonia flowing at an average temperature of -35°C, while maintaining the insulated pipe outer surface temperature at 10°C.
Plot the displacement diagram for a cam with roller follower of diameter 10 mm. The required
motion is as follows;
1- Rising 60 mm in 135° with uniform acceleration and retardation motion.
2- Dwell 90°
3- Falling 60 mm for 135° with Uniform acceleration-retardation motion.
Then design the cam profile to give the above displacement diagram if the minimum circle
diameter of the cam is 50 mm.
Q1/ A vertical, circular gate with water on one side as shown. Determine
the total resultant force acting on the gate and the location of the center of
pressure, use water specific weight 9.81 kN/m³
1 m
4 m
I need handwritten solution with sketches for each
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.