INSTRUMENTAL ANALYSIS-ACCESS >CUSTOM<
7th Edition
ISBN: 9781337783439
Author: Skoog
Publisher: CENGAGE C
expand_more
expand_more
format_list_bulleted
Question
Chapter 3, Problem 3.24QAP
Interpretation Introduction
Interpretation:
The output voltage of an integrator 1, 3, 5, and 7 s after the start of integration needs to be plotted.
Concept introduction:
The output voltage can be calculated as follows:
Here,
V0 = output voltage
Ri = input resistor
C = feedback capacitor
Vi = input voltage
T = time
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
The classical dissociation constant of propionic acid, C2H5CO2H, is 1.34 x10-5 moldm-3 at 250C and the limiting molar conductivities at zero concentration of hydrogen and propionate ions are 349.8 and 35.8 ohm-1 cm2 mol-1 respectively. Calculation of the resistivity of 0.100 M solution of propionic acid.
A standard solution was prepared containing 10.0 ppm of an analyte and 15.0 ppm of an internal standard. Analysis of the sample gave signals for the analyte and internal standard of 0.155 and 0.233 (arbitrary units), respectively. Sufficient internal standard was added to an unknown sample to make it 15.0 ppm in the internal standard. Analysis of the unknown sample yielded signals for the analyte and internal standard of 0.274 and 0.198, respectively. Calculate the concentration of analyte in the unknown sample.
Electrochemical detection is commonly used in combination capillary electrophoresis systems.
This is a type of hydrodynamic voltammetry called flow injection, where it has been shown that
ilim a U1/3, where U is the flow rate of the solution.
Flow analysis of a urine sample at a thin-layer amperometric detector, with a flow-rate of
1.25mL/min, yielded a limiting current value of 1.6µA for its unknown uric acid content. A
larger current of 2.4µA was observed for a sample containing 1 × 10-4 M uric acid and flowing
at a rate of 0.9mL/min. Calculate the original concentration of uric acid in the sample
Chapter 3 Solutions
INSTRUMENTAL ANALYSIS-ACCESS >CUSTOM<
Ch. 3 - Prob. 3.1QAPCh. 3 - Prob. 3.2QAPCh. 3 - Prob. 3.3QAPCh. 3 - Prob. 3.4QAPCh. 3 - Prob. 3.5QAPCh. 3 - Prob. 3.6QAPCh. 3 - Prob. 3.7QAPCh. 3 - Prob. 3.8QAPCh. 3 - Prob. 3.9QAPCh. 3 - Prob. 3.10QAP
Ch. 3 - Prob. 3.11QAPCh. 3 - Prob. 3.12QAPCh. 3 - Prob. 3.13QAPCh. 3 - Prob. 3.14QAPCh. 3 - Prob. 3.15QAPCh. 3 - Prob. 3.16QAPCh. 3 - Prob. 3.17QAPCh. 3 - Prob. 3.18QAPCh. 3 - Prob. 3.19QAPCh. 3 - Prob. 3.20QAPCh. 3 - Prob. 3.21QAPCh. 3 - Prob. 3.22QAPCh. 3 - Prob. 3.23QAPCh. 3 - Prob. 3.24QAPCh. 3 - Prob. 3.25QAP
Knowledge Booster
Similar questions
- P1B.1 A rotating slotted-disc apparatus consists of five coaxial 5.0 cm diameter discs separated by 1.0 cm, the radial slots being displaced by 2.0° between neighbours. The relative intensities, I, of the detected beam of Kr atoms for two different temperatures and at a series of rotation rates were as follows: v/Hz 20 40 80 100 120 I (40 K) 0.846 0.513 0.069 0.015 0.002 I (100 K) 0.592 0.485 0.217 0.119 0.057 Find the distributions of molecular velocities, f(v,), at these temperatures, and check that they conform to the theoretical prediction for a one-dimensional system for this low-pressure, collision-free system.arrow_forwardDesign a voltage divider biased common emitter amplifier with a bypassed emitter resistance for a DC supply of Vcc D (18+R)V and a quiescent current of 2mA. The voltage drop across collector should be 40% of DC supply voltage For the given design conditions: R = 02 Compute the circuit resistances.biased values of voltages and currents. Draw the completely labelled circuit diagram.arrow_forwardKindly answer no iii, iv & varrow_forward
- The resistance of a conductivity cell containing a 0.01 mol KCl solution cm-3 is 150 Ω and the conductivity of this KCl solution is 1.41 × 10-3 Ω-1 cm-1. The same conductivity cell resulting in a resistance of 51.40 Ω for 0.01 HCl solution mol cm-3. Calculate a cell constant and conductivity of the HCl solution.arrow_forwardSuppose the concentration of a solute decays linearly along the length of a container according to c(x) = c0 - αc0x, where c0 is the concentration at x = 0. Calculate the thermodynamic force on the solute at 25 °C and at x = 10 cm and 20 cm given that the concentration falls to 1/2c0 when x = 10 cm. Hint: Start by finding the value of α.arrow_forwardThe molar absorptivity for aqueous solutions of phenol at 211 nm is 6.17 × 103 L cm-1 mol-1. Calculate the permissible range of phenol concentrations if the transmittance is to be less than 85% and greater than 7% when the measurements are made in 1.00-cm cells.arrow_forward
- A student measured the resistance of a 0.5 M NaCl solution to be 45 Ω. Calculate the experimental value of the molar conductivity of this solution if the value of Kcell is 0.0083 cm-1 .arrow_forwardThe molar absorptivity for aqueous solutions of phenol at 211 nm is 6.17 x 103 L cml mol-'. Calculate the permissible range of phenol concentrations if the transmittance is to be less than 85% and greater than 7% when the measurements are made in 1.00-cm cells.arrow_forwardCalculate the distance between the metal and the OHP layer from the Helmholtz model, when the differential capacitance of the electrode is 155 microF cm-2.Data: dielectric strength of the medium for the interfacial zone epsilonr = 50, dielectric strength of the vacuum epsilon0 = 8.85·10-12 F m-1arrow_forward
- Use the data in Table 19D.1 for the exchange-current density and transfer coefficient for the reaction Fe3+ + e− → Fe2+ on platinum at 25 °C to identify the current density needed to obtain an overpotential of 0.30 V as calculated (i) by using the Butler–Volmer equation, and (ii) by assuming that the current is entirely anodic. Comment on the validity of the latter assumption.arrow_forward3) The solution taken from a factory waste sample to prepare an internal standard contains Pb + 2 and Ag + 2, and the analysis peaks were determined as 298 mAU and 324 mAU. To analyze the unknown, a solution containing 0.150 M, 50.0 mL of Ag + 2 is put into the unknown liquid and completed to 100.0 mL. When the peaks are measured again, 670 mAU and 856 mAU signals are read from the samples. What is the concentration of Pb + 2 in the unknown liquid?arrow_forwardKindly answer no i, ii & iiiarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning