The reciprocal of resistance is:
(a) voltage
(b) current
(c) conductance
(d) coulombs
Find the appropriate option that suits for reciprocal of resistance from given options.
Answer to Problem 1RQ
The reciprocal of resistance is “(c) conductance”.
Explanation of Solution
Discussion:
Resistance is defined as the capacity of an element to oppose the flow of electric current. It is denoted as R and its unit is ohm
From Ohm’s law, the resistance is stated as the ratio of voltage to current that is
In a short circuit element, the resistance will be around 0 ohms and in an open circuit element, the resistance would be around infinity.
Conductance is defined as the ability of an element to allow the flow of electric current. It is denoted as G and its unit is mho or siemens (S).
Therefore, the resistance is inversely proportional to the conductance that is
Hence, the option c is correct and remaining options a, b and d are incorrect.
Conclusion:
Thus, the reciprocal of resistance is “(c) conductance”.
Want to see more full solutions like this?
Chapter 2 Solutions
Fundamentals of Electric Circuits
Additional Engineering Textbook Solutions
Thinking Like an Engineer: An Active Learning Approach (4th Edition)
Vector Mechanics for Engineers: Statics and Dynamics
Starting Out With Visual Basic (8th Edition)
Automotive Technology: Principles, Diagnosis, And Service (6th Edition) (halderman Automotive Series)
Fluid Mechanics: Fundamentals and Applications
Mechanics of Materials (10th Edition)
- need a soluarrow_forwardQ1. A 450 V, 50 Hz, 1450 r.p.m., 25 kW, star-connected three-phase induction motor delivers constant (rated) torque at all speeds. The motor equivalent circuit parameters at rated frequency are R1=0.12, R2 = 0.17 2, X₁ = 0.3 2, X2 = 0.5 2, Xm = 23.6 2. Smooth speed variation is obtained by primary frequency control with simultaneous variation of the terminal voltage to maintain constant air-gap flux. Calculate the motor current, power factor and efficiency at one-fifth of rated speed.arrow_forwardQ2. Drive the transformations for currents between a rotating balanced two phase (a,ẞ) winding and a pseudo stationary two phase (d,q) wingding.arrow_forward
- The formulas that should be used to solve the question are in the second picture, also B = k/n a= l/carrow_forward"I need proof in the solution and a supported source with the solution." Write a 8086 microprocessor program to clear (100) consecutive memory locations starting at offset address 8000H. Assume the data segment value equal to 3000H write an 8086 microprocessor program to add two numbers each of four bytes. The first number (least significant byte) starts at memory offset 0500H and the second number (least significant byte) start at offset memory address 0600H Assume the data segment value equal to 0100H.Store the result at memory offset starts 0800H write a program to move a block of 100 numbers consecutive bytes of data strings at offset address 8000 H in memory to another block of memory locations starting at offset address A000 H. assume that both blocks are in the same data segment value 3000H (25 Marks) Write a program to multiply AX by (10.5) using shift instructionarrow_forwardsolve simultaneous equation for the analogue computer given in figurearrow_forward
- 5.2 Explain how a rotating commutator winding may be represented as an equivalent pseudo-stationary coil along the brush axis, and describe the special properties of this type of coil. Write the general voltage and torque equations for the two-pole commutator machine shown in Fig. Prob. 5.2. Explain how the rotational inductance coefficients (G) may be obtained in terms of the Land 1 inductance coefficients. q-axis 9 Fig. Prob. 5.2 d-axisarrow_forward(b) Derive the steady state voltage equations for a compensated metadyne generator shown in Fig.1 A 2kW, 200V, 1500rpm, 2-pole fully compensated metadyne generator has the following parameters: Field self inductance and resistance 30Η, 200Ω Armature self inductance and resistance 0.067, 1 Ω - Field armature mutual inductance 1.2H Calculate for steady state operation, the field current and power gain at rated output. 19-axis १६ Fig. 1 Laxis -arrow_forwardQ2: Determine the suitable auto-transformation ratio for starting a 3-phase induction motor with line current not exceeding three times the full-load current. The short-circuit current is 5 times the full-load current and full-load slip is 5%. Estimate also the starting torque in terms of the full-load torque.arrow_forward
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,