Concept explainers
Interpretation:
The formula of the ion responsible for the base peak is to be determined.
Concept introduction:
In a mass spectrometer, the molecules of the compound are bombarded with high energy electrons. This generally results in one electron from the molecule being knocked out. The resulting ion is a radical ion with an odd number of electrons, called the molecular ion. Since the mass of an electron is negligible, the mass of the molecule and the molecular ion are essentially the same.
The molecular ion is a high energy species and breaks up into a number of fragments, one of which carries the charge. Another source of fragmentation is the bombarding electrons themselves. These electrons often have energies sufficient to not just knock out an electron but also enough to break bonds.
The only species detected in the mass spectrometer are the charged species and their separation is based on the
The mass spectrum shows the distribution of the relative abundance of various ion fragments as a function of their
This means the
The most abundant ion, however, is not the molecular ion. In most cases, it is of a lower mass. The peak for this ion is called the base peak. The spectrum is scaled so that the base peak is 100% relative abundance.
Want to see the full answer?
Check out a sample textbook solutionChapter 16 Solutions
EBK GET READY FOR ORGANIC CHEMISTRY
- Nonearrow_forward4. Draw and label all possible isomers for [M(py)3(DMSO)2(CI)] (py = pyridine, DMSO dimethylsulfoxide).arrow_forwardThe emission data in cps displayed in Table 1 is reported to two decimal places by the chemist. However, the instrument output is shown in Table 2. Table 2. Iron emission from ICP-AES Sample Blank Standard Emission, cps 579.503252562 9308340.13122 Unknown Sample 343.232365741 Did the chemist make the correct choice in how they choose to display the data up in Table 1? Choose the best explanation from the choices below. No. Since the instrument calculates 12 digits for all values, they should all be kept and not truncated. Doing so would eliminate significant information. No. Since the instrument calculates 5 decimal places for the standard, all of the values should be limited to the same number. The other decimal places are not significant for the blank and unknown sample. Yes. The way Saman made the standards was limited by the 250-mL volumetric flask. This glassware can report values to 2 decimal places, and this establishes our number of significant figures. Yes. Instrumental data…arrow_forward
- 7. Draw a curved arrow mechanism for the following reaction. HO cat. HCI OH in dioxane with 4A molecular sievesarrow_forwardTry: Convert the given 3D perspective structure to Newman projection about C2 - C3 bond (C2 carbon in the front). Also, show Newman projection of other possible staggered conformers and circle the most stable conformation. Use the template shown. F H3C Br Harrow_forwardNonearrow_forward
- Organic Chemistry: A Guided InquiryChemistryISBN:9780618974122Author:Andrei StraumanisPublisher:Cengage Learning