Textbook Question
Chapter 10, Problem 8SQ
Refer to the circuit shown in Figure 10–6. Assume that when the thermostat contact closes nothing happens. Which of the following could NOT cause this condition?
a. The high-pressure switch is open.
b. The CCOL contact is open.
c. The low-pressure switch is open.
d. he coil of the compressor contactor is open.
Fig. 10–6 Pressure switches are often used in air-conditioning circuits.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Do all with Explanation
Write troubleshooting and maintenance of
the three-phase separator ( show your
answer in table)
Answer all the following questions
Chapter 10 Solutions
Electric Motor Control
Ch. 10 - Describe how pressure switches are connected to...Ch. 10 - What type of pressure switch is generally used to...Ch. 10 - A pressure switch is set to cut in at a pressure...Ch. 10 - A pressure switch is to be installed on a system...Ch. 10 - A pressure switch is to be installed in a circuit...Ch. 10 - Refer to the circuit shown in Figure 105. If the...Ch. 10 - Refer to the circuit shown in Figure 105. Assume...Ch. 10 - Refer to the circuit shown in Figure 106. Assume...Ch. 10 - Refer to the circuit shown in Figure 106. Assume...Ch. 10 - Refer to Figure 106. When the thermostat contact...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- a. Draw the relationship between excitation current and short circuit, and Please explain. b. At what volts is the alternator end voltage short-circuited? At nominal voltage What will happen if a short circuit is made?arrow_forwardcontrol systemQ/ Do you observe any relation between the system damping ratio and thesystem settling time.arrow_forwardWhy PMMC Voltmeters can not be used to measure higher voltages directly? a. because the size of the coils will raise b. because the coils will not be present at all c. because of the lesser current ratings. d. because of the lesser size problemsarrow_forward
- 1. In an automatic mixing operation the sequence of operation is as follows: When the start button is pressed fill the tank with Liquid B till it reaches X1 and then fill the tank with Liquid A till it reaches X2. Once the level of Liquid reaches X2, turn on the motor for another 20 seconds for mixing process. After the timer stops timing, empty the tank by opening the mixture outlet. X1 and X2 are capacitive proximity sensors and there are start, stop and emergency stop push buttons. XO START X1 STOP YO (Liquid A Inlet ) EMERGENCY STOP YI(Liquid B Inlet) Y2(Mixture Outlet) For the system explained above answer the following: a) Provide the Allocation List b) Draw the Grace and extract the grafcet equation c) Draw the Ladder Diagramarrow_forwardExplain with figure forced circulation solar water heater.arrow_forwardWhat are the functions of a Transfer Switch: (Select all answers that apply) Group of answer choices A. Shifts electrical power from the normal utility power source to the standby power source B. Isolates the utility source from the standby source in such a way that there is no feedback from the generator to the utility’s system or vice versa C. When normal power is restored, the automatic transfer switch resets itself and is ready for the next power outage D. Provides for measuring of power usage by the residents during periods of brownouts with the generator offline.arrow_forward
- Refer to the circuit shown in Figure 106. Assume that when the thermostat contact closes the compressor does not start, but the condenser fan and evaporator fan do start. When troubleshooting the circuit, a voltmeter connected across the compressor contactor coil CC indicates 0 volts. A voltmeter connected across the high-pressure switch indicates 0 volts, and a voltmeter placed across the thermostat contact indicates 0 volts. When the voltmeter is connected across the low-pressure switch it indicates 24 volts. Which of the following conditions could cause this problem? a. The refrigerant pressure is too high. b. The compressor contactor coil is open. c. The refrigerant pressure is too low. d. The thermostat contact is open. Fig. 106 Pressure switches are often used in air-conditioning circuits.arrow_forwardTechnician A says when testing the voltage output, if the charging voltage is too high, the cause could be an open field wire from the regulator. Technician B says a loose or glazed drive belt could be the cause of too high charging voltage. Who is correct? A only B only Both A and B Neither A or B Technician A says that poor connection at the generator output wire can cause charging systems problems. Technician B says that many charging system circuits contain a circuit protection device. Who is correct? A only B only Both A and B Neither A or Barrow_forwardDesign a ladder program to run the material mixing system according to the following information: 1- When the start push button I0.0 is pressed, the pump (PUMP1 Q0.0) works for five seconds and then stops. 2- After that, the pump (PUMP2 Q0.1) runs for three seconds and then stops. 3- After that the pump (Mixer Motor Q0.2) works for 60 sec and then stops. 4- After that, the control valve (drian valve Q0.3) is opened, the pump (PUMP3 Q0.4) works for ten seconds. 5- The stop push button I0.1 is used to stop the system.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Electricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
Pressure Sensors with Display; Author: Balluff Worldwide;https://www.youtube.com/watch?v=HqAV2xjCLxE;License: Standard Youtube License