Electric Motor Control
10th Edition
ISBN: 9781133702818
Author: Herman
Publisher: CENGAGE L
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 10, Problem 6SQ
Refer to the circuit shown in Figure 10–5. If the pressure should become high enough for the pressure switch to close and stop the motor, is it possible to restart the motor before the pressure drops to a safe level?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
what are designed to protect the motor from an overload condition
c) Based on Figure 3 (c), a basic DOL starter induction motor at a power station is
experiencing run-time error and unable to start, based on your understanding,
interpret the sequence of troubleshooting shall be carried out to identify the root
cause of the abnormalities.
3P
1P
MCB
MCB
STOP
K1
START
MOTOR
Figure 3 (c)
Define or state the principle of operation, draw the wiring diagram, discuss the construction and application of each motor
Split phase capacitor motor
Repulsion motor
Chapter 10 Solutions
Electric Motor Control
Ch. 10 - Describe how pressure switches are connected to...Ch. 10 - What type of pressure switch is generally used to...Ch. 10 - A pressure switch is set to cut in at a pressure...Ch. 10 - A pressure switch is to be installed on a system...Ch. 10 - A pressure switch is to be installed in a circuit...Ch. 10 - Refer to the circuit shown in Figure 105. If the...Ch. 10 - Refer to the circuit shown in Figure 105. Assume...Ch. 10 - Refer to the circuit shown in Figure 106. Assume...Ch. 10 - Refer to the circuit shown in Figure 106. Assume...Ch. 10 - Refer to Figure 106. When the thermostat contact...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Refer to the circuit shown in Figure 105. Assume that the motor is running and an overload occurs, which causes the OL contact to open and disconnect coil M to stop the motor. What effect does the opening of the overload contact have on the pressure switch circuit?arrow_forwardDescribe how pressure switches are connected to start and stop (a) small motors and (b) large motors.arrow_forwardWhat provides the running overload protection for the pump motor? ______arrow_forward
- Please solve this question in control system quicklyarrow_forward٥arrow_forwardAssume all of the timers are set for a 3 second delay. When the start button is pressed, nothing happens. None of the motors start. Which of the following could NOT cause this problem. a Overload contact OL1 is open b 1CR relay coil is open c 2CR relay coil is open d The stop button is openarrow_forward
- synchronous motorarrow_forwardHow can you determine the current that a direct current motor will draw at start-up?arrow_forwardyou are working as a plant electrician. you are told that a large DC motor was returned from the rewind shop and was installed on the previous shift. the motor seemed to operate properly until load was added, the motor then stopped, reversed direction, and began to run at a high speed. what is the probable cause of the trouble, and what would you do to correct the problem?arrow_forward
- Make a diagram.arrow_forward1. It is a machine that converts mechanical energy to electrical energy. 2. It is a machine that converts electrical energy to mechanical energy. 3. It is cylindrical or drum-shaped where the coils are placed and can either be lap wounded or wave wounded. 4. It connects the commutator to the other parts of the DC machine. 5. It serves as the housing of the dc machine. 6. True or False: The shunt field winding is part of the armature. 7. True or False: The long shunt compound generator is when the armature is in series with the series field winding and parallel to the shunt field winding. 8-10. Your newly built house needs an elevator. Which from the following will be best to use- series, shunt or compound motor and why?arrow_forwardSelect the best answer for each of the following. If an operator pushes a start button on a three-phase induction motor and the motor starts to hum, but not run, the probable trouble is a. one fuse is blown and the motor is single phasing. b. the overload trip needs resetting. c. the auxiliary contact is shorted. d. one phase is grounded.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Electricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage LearningEBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Pressure Sensors with Display; Author: Balluff Worldwide;https://www.youtube.com/watch?v=HqAV2xjCLxE;License: Standard Youtube License