Interpretation:
A standard drinking straw is 23 cm tall. Pressure difference needed to raise a column of water to that high is to be calculated. Given density of water is 1.0 g/cm3 and g is 9.80 m/s2
Concept introduction:
Pressure can be defined as a force acting on per unit area i.e.,
P = F/A,
Where, F = force,
A = area on which the force is acted.
Pressure can be conveniently measured for gases and fluids. The pressure of a liquid or a gas is equal to the density of that liquid multiplied by the acceleration due to gravity and the height of the liquid above the certain point. The standard unit for pressure is Pascal (Pa). Other units of pressure, such as pounds per square inch and bar, are also commonly used. The pressure units can also be expressed in grams-force or kilograms-force per square centimeter, without properly identifying the force units. The standard atmosphere (atm) is approximately equal to typical air pressure at earth mean sea level and is having the value of 101325 Pa. Since, Pressure is most prevalently measured by its tendency to displace a column of liquid in a manometer, it is also expressed as depth of a fluid. For example: Centimeters of water (or) millimeters of mercury.

Trending nowThis is a popular solution!

Chapter 1 Solutions
Student Solutions Manual for Ball's Physical Chemistry, 2nd
- I have a 2 mil plastic film that degrades after 22 days at 88C and at 61C takes 153 days. What is the failure at 47C in days.arrow_forwardIf a 5 film plastic film degraded in 30 days at 35C and the same film degraded in 10 days at 55 C and 2 days at 65C what would the predicted life time be at 22C for the same film?arrow_forwardno Ai walkthroughsarrow_forward
- I have a aqueous solution (175 ml) of iridium trichloride containing 8,750 ppm Iridium by ICP OES analysis. What is the percent concentration of Iridium trichloride in aquous solution and provide the concentration in moles per liter, percentage by weight.arrow_forwardno Ai walkthroughsarrow_forwardno Ai walkthroughsarrow_forward
- no Ai walkthroughs (product in picture is wrong btw don't submit the same thing)arrow_forwardno Ai walkthroughsarrow_forward136 PRACTICAL SPECTROSCOPY Compound 78 is a high-boiling liquid (boiling point 189° C) that contains halogen, but will not react with alkoxides to yield an halogen. ether. The Mass, IR, and 'H NMR spectra, along with 13C NMR data, are given below. Elemental Analysis: C, 35.32; H, 2.47; contains BC Spectral Data: doublet, 137.4 ppm; doublet, 130.1 ppm; doublet, 127.4 ppm; singlet, 97.3 ppm Absorbance Mass Spectrum Intensity 77 77 204 M + 128 40 60 80 100 120 140 160 180 m/e 200 220 280 240 260 300 Infrared Spectrum Wave Number, cm -1 4000 3000 2500 2000 1500 1300 1200 1100 1000 900 800 700 3 6 7 8 9 10 12 13 15 Wavelength, microns 'H NMR wwwww 5 Structure: www ppm, & ©2000 Brooks/Cole Publishing Com-arrow_forward
- Chemistry: Matter and ChangeChemistryISBN:9780078746376Author:Dinah Zike, Laurel Dingrando, Nicholas Hainen, Cheryl WistromPublisher:Glencoe/McGraw-Hill School Pub CoChemistryChemistryISBN:9781305957404Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCostePublisher:Cengage LearningChemistry: An Atoms First ApproachChemistryISBN:9781305079243Author:Steven S. Zumdahl, Susan A. ZumdahlPublisher:Cengage Learning
- Chemistry: The Molecular ScienceChemistryISBN:9781285199047Author:John W. Moore, Conrad L. StanitskiPublisher:Cengage LearningIntroductory Chemistry: A FoundationChemistryISBN:9781337399425Author:Steven S. Zumdahl, Donald J. DeCostePublisher:Cengage Learning




