Which of the following is not a problem with linking an MS to HPLC? Select one: O a. The inorganic buffer salts in the mobile phase which accumulate in the MS O b. The different compounds that have similar masses but which can be separated by HPLC but appear as they belongs to the same compound in MS O c. The unlimited masses that the HPLC device can separate into limited masses that cannot exceed 4000 mu in the MS O d. Removal of the liquid mobile phase of HPLC which does not fit with the vacuum operation in the MS O e. Transition from a reduced HPLC temperature (<50 ° C) to elevated temperature exceeding 200 °C in MS

Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
icon
Related questions
Question
Which of the following is not a problem with linking an MS to HPLC?
Select one:
O a. The inorganic buffer salts in the mobile phase which accumulate in the MS
O b. The different compounds that have similar masses but which can be separated by
HPLC but appear as they belongs to the same compound in MS
O c. The unlimited masses that the HPLC device can separate into limited masses that
cannot exceed 4000 mu in the MS
O d. Removal of the liquid mobile phase of HPLC which does not fit with the vacuum
operation in the MS
O e. Transition from a reduced HPLC temperature (<50 C) to elevated temperature
exceeding 200 ° C in MS
Transcribed Image Text:Which of the following is not a problem with linking an MS to HPLC? Select one: O a. The inorganic buffer salts in the mobile phase which accumulate in the MS O b. The different compounds that have similar masses but which can be separated by HPLC but appear as they belongs to the same compound in MS O c. The unlimited masses that the HPLC device can separate into limited masses that cannot exceed 4000 mu in the MS O d. Removal of the liquid mobile phase of HPLC which does not fit with the vacuum operation in the MS O e. Transition from a reduced HPLC temperature (<50 C) to elevated temperature exceeding 200 ° C in MS
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Mass Spectrometry
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Organic Chemistry
Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY