Two three-phase generating power stations, A and B, work at 97 kV and deliver power to their respective consumers as follows: Power station A delivers 900 MVA to its consumers at a power factor of 0.766 lagging.  Power station B delivers 600 MVA to its consumers at a power factor of 0.819 lagging.  An interconnector with an impedance of (1.5 + j5.6) Ω per line is connected between A   and B. The voltage at power station A is advanced with an angle of 9° with respect to the voltage at power station B. Use the complex power method and do the following calculations. Determine the total active power delivered or received by Power station A (Pi) in MW Determine the total reactive power delivered or received by Power station A (Qi) in MVAr Determine the total active power delivered or received by Power station B (Pj) in MW.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

Two three-phase generating power stations, A and B, work at 97 kV and deliver power to their respective consumers as follows:

Power station A delivers 900 MVA to its consumers at a power factor of 0.766 lagging.

 Power station B delivers 600 MVA to its consumers at a power factor of 0.819 lagging.

 An interconnector with an impedance of (1.5 + j5.6) Ω per line is connected between A   and B. The voltage at power station A is advanced with an angle of  with respect to the voltage at power station B.

Use the complex power method and do the following calculations.

Determine the total active power delivered or received by Power station A (Pi) in MW

Determine the total reactive power delivered or received by Power station A (Qi) in MVAr

Determine the total active power delivered or received by Power station B (Pj) in MW.

Determine the total reactive power delivered or received by Power station B (Qj) in MVAr

Use complex power method to determine the final reactive power loadings (Qa) on Power station A  in MVar.

Use complex power method to determine the final active power loadings on Power station B (Pb) in MW.

Use complex power method to determine the final reactive power loadings (Qb)  oPower station B  in MVAr.

Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Analysis of Single Phase and Three Phase System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,