Two power system areas operating at a nominal frequency of 60 Hz are connected with a tie line, and have the following characteristics: Area 1: R1 = 0.02 pu and D1 = 1 pu on a base of 1200 MVA Area 2: R2 = 0.03 pu and D2 = 0.8 pu on a base of 700 MVA The power flow direction on the tie line is from Area 1 to Area 2. Using a common base of 1000 MVA, what is the change in tie flow (in MW) for a load increase of 200 MW in Area 1? Select one: a.-56.16 MW O b. None of these O c.-143.84 MW O d.-38.02 MW
Two power system areas operating at a nominal frequency of 60 Hz are connected with a tie line, and have the following characteristics: Area 1: R1 = 0.02 pu and D1 = 1 pu on a base of 1200 MVA Area 2: R2 = 0.03 pu and D2 = 0.8 pu on a base of 700 MVA The power flow direction on the tie line is from Area 1 to Area 2. Using a common base of 1000 MVA, what is the change in tie flow (in MW) for a load increase of 200 MW in Area 1? Select one: a.-56.16 MW O b. None of these O c.-143.84 MW O d.-38.02 MW
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter6: Power Flows
Section: Chapter Questions
Problem 6.61P
Related questions
Question
![Two power system areas operating at a nominal frequency of 60 Hz are connected with a tie line, and have the following characteristics:
Area 1: R1 = 0.02 pu and D1 = 1 pu on a base of 1200 MVA
Area 2: R2 = 0.03 pu and D2 = 0.8 pu on a base of 700 MVA
The power flow direction on the tie line is from Area 1 to Area 2.
Using a common base of 1000 MVA, what is the change in tie flow (in MW) for a load increase of 200 MW in Area 1?
Select one:
a.-56.16 MW
O b. None of these
O c.-143.84 MW
O d.-38.02 MW
<](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2Fd99b6acb-3c56-46a2-8aaf-762988209417%2F740fc309-949b-4ed6-b413-fa94e3358f18%2F64pknno_processed.jpeg&w=3840&q=75)
Transcribed Image Text:Two power system areas operating at a nominal frequency of 60 Hz are connected with a tie line, and have the following characteristics:
Area 1: R1 = 0.02 pu and D1 = 1 pu on a base of 1200 MVA
Area 2: R2 = 0.03 pu and D2 = 0.8 pu on a base of 700 MVA
The power flow direction on the tie line is from Area 1 to Area 2.
Using a common base of 1000 MVA, what is the change in tie flow (in MW) for a load increase of 200 MW in Area 1?
Select one:
a.-56.16 MW
O b. None of these
O c.-143.84 MW
O d.-38.02 MW
<
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 3 steps with 4 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
![Power System Analysis and Design (MindTap Course …](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
![Electricity for Refrigeration, Heating, and Air C…](https://www.bartleby.com/isbn_cover_images/9781337399128/9781337399128_smallCoverImage.gif)
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning
![Power System Analysis and Design (MindTap Course …](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
![Electricity for Refrigeration, Heating, and Air C…](https://www.bartleby.com/isbn_cover_images/9781337399128/9781337399128_smallCoverImage.gif)
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning