There is a 16- Story building where the street Pressure is reported as 45 psi. The highest outlet 180 ft above the level of the pumps and the at the same level as the street main. Pumps are is The building has flush valve water closets and the required pressure at the highest fixture is 20 psi. The total combined cold and hot water fixture count for the building is 4900 F.u. The length of run from the pumps to the farthest and height fixture is 350 ft. Material for the Water Service into the building will be type Capper piping. Calculate the pump Capacity in Ps; and the design the main pipe ( head loss through pumps is 5 PS: (

Residential Construction Academy: House Wiring (MindTap Course List)
4th Edition
ISBN:9781285852225
Author:Gregory W Fletcher
Publisher:Gregory W Fletcher
Chapter14: Branch-circuit Installation
Section: Chapter Questions
Problem 11RQ
icon
Related questions
Question
There is
a
16- Story building where the street
Pressure is reported
as
45 psi. The highest outlet
180 ft above the level of the pumps and the
at the same level as the street main.
Pumps are
is
The building has flush valve water closets and
the required pressure at the highest fixture is
20 psi. The total combined cold and hot water
fixture count for the building is 4900 F.u. The
length of run from the pumps to the farthest
and height fixture is 350 ft. Material for the
Water Service into the building will be type Capper
piping. Calculate the pump Capacity in Ps; and
the design the main pipe ( head loss through pumps is
5 PS:
(
Transcribed Image Text:There is a 16- Story building where the street Pressure is reported as 45 psi. The highest outlet 180 ft above the level of the pumps and the at the same level as the street main. Pumps are is The building has flush valve water closets and the required pressure at the highest fixture is 20 psi. The total combined cold and hot water fixture count for the building is 4900 F.u. The length of run from the pumps to the farthest and height fixture is 350 ft. Material for the Water Service into the building will be type Capper piping. Calculate the pump Capacity in Ps; and the design the main pipe ( head loss through pumps is 5 PS: (
Expert Solution
steps

Step by step

Solved in 2 steps with 3 images

Blurred answer
Similar questions
Recommended textbooks for you
Residential Construction Academy: House Wiring (M…
Residential Construction Academy: House Wiring (M…
Civil Engineering
ISBN:
9781285852225
Author:
Gregory W Fletcher
Publisher:
Cengage Learning
Solid Waste Engineering
Solid Waste Engineering
Civil Engineering
ISBN:
9781305635203
Author:
Worrell, William A.
Publisher:
Cengage Learning,
Construction Materials, Methods and Techniques (M…
Construction Materials, Methods and Techniques (M…
Civil Engineering
ISBN:
9781305086272
Author:
William P. Spence, Eva Kultermann
Publisher:
Cengage Learning
Residential Construction Academy: House Wiring (M…
Residential Construction Academy: House Wiring (M…
Civil Engineering
ISBN:
9781337402415
Author:
Gregory W Fletcher
Publisher:
Cengage Learning
Steel Design (Activate Learning with these NEW ti…
Steel Design (Activate Learning with these NEW ti…
Civil Engineering
ISBN:
9781337094740
Author:
Segui, William T.
Publisher:
Cengage Learning
Engineering Fundamentals: An Introduction to Engi…
Engineering Fundamentals: An Introduction to Engi…
Civil Engineering
ISBN:
9781305084766
Author:
Saeed Moaveni
Publisher:
Cengage Learning