Textbook Question
Chapter 13, Problem 1RQ
Explain how the NEC® and Underwriters Laboratories categorize general-use snap switches. (Objective 13-1)
Expert Solution & Answer
![Check Mark](/static/check-mark.png)
To determine
Categorization of snap switches by NEC and Underwriters Laboratories.
Explanation of Solution
General use snap switches are defined as the switches which are used for controlling the equipment and preventing arcing of the switch due to the ignition of the external atmosphere. These switches can be installed in device boxes or used in the wiring system.
According to NEC and underwriters laboratories, these switches are categorized into two types.
- Alternating current general use switch − As their name suggests these switches can be used only for a circuit having alternating current flowing through it. These switches control the following values as per section 404.14(A) of article number 404 of NEC controls.
- Motor loads −The motor loads whose rating is less than 80 % of the ampere rating of the switch at the given voltage.
- Lamp load − A load of a lamp having filament of tungsten and having a rating less than the rating of the switch at 120 V.
- Resistive and inductive loads − Loads if a rating is less than the ampere rating of the switch at the voltage at which the switch operates.
- Direct current or alternating current general use switch − These switches can be used for the circuits having alternating current or direct current flowing through it. These switches control the following values as per section 404.14(B) of article number 404 of NEC controls.
- Inductive loads −Its values are controlled if the rating is less than 50 % of the ampere rating of the switch at the given voltage.
- Lamp load − A load of a lamp having filament of tungsten is controlled if it has a rating less than the rating of the switch at applied voltage.
- Resistive load− It is controlled if its rating is less than the ampere rating of the switch at the voltage at which the switch operates.
Want to see more full solutions like this?
Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
2. Determine the centroid and moment of inertia, lxx.
a)
2in x 4in
1in x 4in
b)
1/2in plywood
metal plate
3/4in x 10in
c-channel
10in x 25in
Ixi = 92.14in1
Aix = 7.35in²
24in
Please provide a handwritten solution to the question
Would impulse be zero since the particles have no external forces acting during the moment of contact? Please solve the entire problem.
Chapter 13 Solutions
Residential Construction Academy: House Wiring (MindTap Course List)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Similar questions
- By using the yield line theory, determine the ultimate resisting moment per linear meter (m) for an isotropic reinforced concrete two-way simply supported triangle slab shown in figure under a uniform load (q). Solve by using equilibrium method m marrow_forwardThe tension in cable BA is 10 kN. The questions will lead you toward determining the moment of the force acting from B to A about the x-axis. Hints: Pay attention to the orientation of the XYZ coordinate axes. 1000 mm A (400, 300, 0) mm 600 mm xarrow_forwardThe beam shown in the figure below is typical for a floor system in an existing building.It needs to carry a uniform live load of 260 lb/ft and a uniform dead weight of 400 lb/ft,including its own weight. The owner wants to add a partition weighing 7 kip (live load) asshown. Assuming the added partition as live load, is the beam section adequate to safelycarry the extra live load?PartitionStirrups15 ft 3 in.14 in.a. Determine the d e s i g n m o m e n t c a p a c i t y .b. D e t e r m i n e t h e f a c t o r e d a p p l i e d b e n d i n g m o m e n t .c. Is the beam safe and adequate for bending? Please explain your response.arrow_forward
- 4. Use the influence function method to draw the influence line for the shear just to the right of A. Assume C is fixed, A is a roller, and B is a pin. 8 ft A 16 ft B 10 ft-arrow_forward4-39. Draw the shear and moment diagrams for each of the three members of the frame. Assume the frame is pin connected at A, C, and D and there is a fixed joint at B. 4 m 50 kN 40 kN -1.5 m -2 m 1.5 B 15 kN/m 6 m Darrow_forwardAggregates from three sources having the properties shown in Table P5.41were blended at a ratio of 25:60:15 by weight. Determine the properties of theaggregate blend.arrow_forward
- 7-7. Determine the equations of the elastic curve for the beam using the x and x, coordinates. Specify the beam's maximum deflection. El is constant. 22arrow_forwardThe cantilever beam shown below supports a uniform service (unfactored) dead load of 1.5 kip/ft plus its own self weight, plus two unknown concentrated service (unfactored) live loads, as shown. The concrete has f’c = 6,000 psi and the steel yield strength is 60 ksi. a. Determine the design moment capacity. b. Set up the applied bending moment capacity. c. Calculate maximum safe concentrated live load that the beam may carry.arrow_forwardThe circular slab of radius r supported by four columns, as shown in figure, is to be isotropically reinforced. Find the ultimate resisting moment (m) per linear meter required just to sustain a concentrated factored load of P kN applied at the center of the slab. Solve by using equilibrium m m Columnarrow_forward
- By using the yield line theory, determine the ultimate resisting moment per linear meter (m) for an isotropic reinforced concrete two-way simply supported polygon slab shown in figure under a uniform load (q). Solve by using equilibrium method m marrow_forwardBy using the yield line theory, determine the ultimate resisting moment per linear meter (m) for an isotropic reinforced concrete two-way simply supported polygon slab shown in figure under a concentrated factored load of P. Solve by Using equilibrium method m m 8/arrow_forwardH.W: Evaluate the integral 1. 30 √ · √(x²y – 2xy)dydx 0-2 3 1 3. (2x-4y)dydx 1-1 2π π 5. (sinx + cosy)dxdy π 0 0 1 ƒ ƒ (x + 2. +y+1)dxdy 4. -1-1 41 ][ 20 x²ydxdyarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Residential Construction Academy: House Wiring (M...Civil EngineeringISBN:9781337402415Author:Gregory W FletcherPublisher:Cengage Learning
![Text book image](https://www.bartleby.com/isbn_cover_images/9781337402415/9781337402415_smallCoverImage.gif)
Residential Construction Academy: House Wiring (M...
Civil Engineering
ISBN:9781337402415
Author:Gregory W Fletcher
Publisher:Cengage Learning
02 - Overview of Circuit Components - Resistor, Capacitor, Inductor, Transistor, Diode, Transformer; Author: Math and Science;https://www.youtube.com/watch?v=RHpo4wKo8pQ;License: Standard Youtube License