The linear absorption coefficients for 0.05-nm x-rays in lead and in iron are, respectively, 5.8 × 10* m¯' and 1.1 x 10* m-. How thick should an iron shield be in order to pro- vide the same protection from these x-rays as 10 mm of lead?