The development lengths and splice lengths specified in ACI Code Sections 25.4.2 and 25.5.2 apply to frames resisting seismic forces except as altered in ACI Code Section 18.8.5.1, which deals with development of bars in beam-column joints. ACI Code Section 18.6.3.3 prohibits lap splices 1. within joints; 2. within 2h from the faces of joints; and 3. in locations where flexural yielding can occur due to lateral deformations of the frame. Lap splices must be enclosed by hoops or spirals at spacing equal to the smaller of 4 in. or d/4. Mechanical splices can be used as limited by ACI Code Section 18.6.3.4. Welding is not encouraged; tack welding of bars for assembly purposes embrittles the bars locally, and thus is not permitted.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
The development lengths and splice lengths specified in ACI Code Sections 25.4.2
and 25.5.2 apply to frames resisting seismic forces except as altered in ACI Code
Section 18.8.5.1, which deals with development of bars in beam-column joints. ACI Code
Section 18.6.3.3 prohibits lap splices
1. within joints;
2. within 2h from the faces of joints; and
3. in locations where flexural yielding can occur due to lateral deformations of the
frame.
Lap splices must be enclosed by hoops or spirals at spacing equal to the smaller of 4 in. or
d/4. Mechanical splices can be used as limited by ACI Code Section 18.6.3.4. Welding is
not encouraged; tack welding of bars for assembly purposes embrittles the bars locally, and
thus is not permitted.
Transcribed Image Text:The development lengths and splice lengths specified in ACI Code Sections 25.4.2 and 25.5.2 apply to frames resisting seismic forces except as altered in ACI Code Section 18.8.5.1, which deals with development of bars in beam-column joints. ACI Code Section 18.6.3.3 prohibits lap splices 1. within joints; 2. within 2h from the faces of joints; and 3. in locations where flexural yielding can occur due to lateral deformations of the frame. Lap splices must be enclosed by hoops or spirals at spacing equal to the smaller of 4 in. or d/4. Mechanical splices can be used as limited by ACI Code Section 18.6.3.4. Welding is not encouraged; tack welding of bars for assembly purposes embrittles the bars locally, and thus is not permitted.
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning