Task III: You were asked to evaluate the efficiency of a 5.5 kW motor that operates on a constant load.  You took the attached photo of the motor nameplate and then you collected the following  measurements: Current = 6.2 A, power factor = 0.81, speed = 2925 rpm. The motors runs daily on  an average of 16 hours. Prepare a short motor assessment note which includes: • The measurements you took, and the equipment you used to obtain such measurements • Calculation of the current motor efficiency • Energy saving measure(s) you would recommend, with a financial feasibility analysis

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

Task III:
You were asked to evaluate the efficiency of a 5.5 kW motor that operates on a constant load. 
You took the attached photo of the motor nameplate and then you collected the following 
measurements: Current = 6.2 A, power factor = 0.81, speed = 2925 rpm. The motors runs daily on 
an average of 16 hours.
Prepare a short motor assessment note which includes:
• The measurements you took, and the equipment you used to obtain such measurements
• Calculation of the current motor efficiency
• Energy saving measure(s) you would recommend, with a financial feasibility analysis

MORE PONNER
TYPE
380VA/660VY
2900
Y2-132S2-2
50
THREE-PHASE
INDUCTION MOTOR
7.5
5.5
11.0/6.33
F
100%
COPPER
Hz
OSG
r/min
INS.CL
IP 55
64
STANDARD JB/T8680-2008 NO.160717093
N.W
HP
KW
A
Kg
Germany standard CE
IS09001
Transcribed Image Text:MORE PONNER TYPE 380VA/660VY 2900 Y2-132S2-2 50 THREE-PHASE INDUCTION MOTOR 7.5 5.5 11.0/6.33 F 100% COPPER Hz OSG r/min INS.CL IP 55 64 STANDARD JB/T8680-2008 NO.160717093 N.W HP KW A Kg Germany standard CE IS09001
Expert Solution
Step 1

According to the question the rating of the motor are as:

Power rating = 5.5 kW

Current = 6.2 A,

Power factor = 0.81

Speed = 2925 rpm.

steps

Step by step

Solved in 4 steps

Blurred answer
Knowledge Booster
Synchronous Generator
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,