Suppose there is a source of N0x in a building that produces 100 µg/s of NOx. Assume that the air inside the building is always well mixed and that the outdoor air has already an N0x concentration of 50 µg/m³. (a) What outdoor airflow is needed (in l/s) to meet the indoor concentration of 100 µg/m³ or less? (b) If the zone bypass factor is 0.2, what should be the outdoor airflow if there is no recirculation of return air? (c) Recalculate (b) if 80% of the air is recirculated.

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question

Suppose there is a source of ??? in a building that produces 100 ??/? of ???.
Assume that the air inside the building is always well mixed and that the outdoor air
has already an ??? concentration of 50 ??/?3.


(a) What outdoor airflow is needed (in ?/?) to meet the indoor concentration of
100 ??/?3 or less?
(b) If the zone bypass factor is 0.2, what should be the outdoor airflow if there is no
recirculation of return air?
(c) Recalculate (b) if 80% of the air is recirculated.

Suppose there is a source of 0x in a building that produces 100 µg/s of N0x.
Assume that the air inside the building is always well mixed and that the outdoor air
has already an nOx concentration of 50 µg/m³.
(a) What outdoor airflow is needed (in l/s) to meet the indoor concentration of
100 µg/m³ or less?
(b) If the zone bypass factor is 0.2, what should be the outdoor airflow if there is no
recirculation of return air?
(c) Recalculate (b) if 80% of the air is recirculated.
Transcribed Image Text:Suppose there is a source of 0x in a building that produces 100 µg/s of N0x. Assume that the air inside the building is always well mixed and that the outdoor air has already an nOx concentration of 50 µg/m³. (a) What outdoor airflow is needed (in l/s) to meet the indoor concentration of 100 µg/m³ or less? (b) If the zone bypass factor is 0.2, what should be the outdoor airflow if there is no recirculation of return air? (c) Recalculate (b) if 80% of the air is recirculated.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 6 steps with 5 images

Blurred answer
Knowledge Booster
Enzymatic and non Enzymatic reactions
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The