Q2. The following readings are taken from the results of an open-circuit and short-circuit tests on a three-phase, Y-connected, 100-kVA, 500V, four-pole, 60HZ turbo-generator: 25 30 Field current (A) O.C.T- VLL Voltage (kV) S.C.T- Armature current (A) 73 10 15 20 125 250 370 480 566 640 146 220 If the measured D.C armature resistance between terminals is 0.42, then Determine: I- The unsaturated synchronous impedance. II- The saturated synchronous impedance. III- The voltage regulation at rated power 0.8 leading power factor and the corresponding field current. IV- The minimum line current the generator can supply at full-load and the corresponding field current.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Q2. The following readings are taken from the results of an open-circuit and short-cırcuit tests
on a three-phase, Y-connected, 100-kVA, 500V, four-pole, 60HZ turbo-generator:
25
30
Field current (A)
O.C.T- VLL Voltage (kV)
S.C.T- Armature current (A) 73
10
15
20
125 250
370 480 566 640
146
220
If the measured D.C armature resistance between terminals is 0.42, then
Determine:
I- The unsaturated synchronous impedance.
II- The saturated synchronous impedance.
III- The voltage regulation at rated power 0.8 leading power factor and the corresponding field current.
IV- The minimum line current the generator can supply at full-load and the corresponding field current.
Transcribed Image Text:Q2. The following readings are taken from the results of an open-circuit and short-cırcuit tests on a three-phase, Y-connected, 100-kVA, 500V, four-pole, 60HZ turbo-generator: 25 30 Field current (A) O.C.T- VLL Voltage (kV) S.C.T- Armature current (A) 73 10 15 20 125 250 370 480 566 640 146 220 If the measured D.C armature resistance between terminals is 0.42, then Determine: I- The unsaturated synchronous impedance. II- The saturated synchronous impedance. III- The voltage regulation at rated power 0.8 leading power factor and the corresponding field current. IV- The minimum line current the generator can supply at full-load and the corresponding field current.
Expert Solution
steps

Step by step

Solved in 8 steps with 4 images

Blurred answer
Knowledge Booster
Synchronous Generator
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,