Q2 / For the connection of Figure 2, in terms of switching surge, when the second terminal of CB is shorting the circuit to the earth, answer the following questions: 1- Plot the equivalent electrical RLC circuit expressing the circuit case. 2- Explain the effect of R, L, and C values on the shape of generated oscillation. 3- Determine the relative attenuation occurring in three cycles in the overvoltage surge set up on a 75 kV cable fed through an air-blast circuit breaker when the breaker opens on a system short circuit. The network parameters are as follows: R= 8.5 0, L = 7.1mH, C= 0.0516 µF

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

Please solve as soon as possible

Q2 / For the connection of Figure 2, in terms of switching surge, when the second terminal of
CB is shorting the circuit to the earth, answer the following questions:
1- Plot the equivalent electrical RLC circuit expressing the circuit case.
2- Explain the effect of R, L, and C values on the shape of generated oscillation.
3- Determine the relative attenuation occurring in three cycles in the overvoltage surge
set up on a 75 kV cable fed through an air-blast circuit breaker when the breaker opens
on a system short circuit. The network parameters are as follows:
R= 8.5 0, L = 7.1mH, C= 0.0516 µF
CB
= Om
VLC
Restriking voltage
(expanded time
scale)
R
21
Maximum Voltage V = 1.633 x Surge voltage
v(t) = V[1 -e cos ont]
Arc voltage
Time
System
voltage
CB open circuit
Fault current
Figure: 2
Transcribed Image Text:Q2 / For the connection of Figure 2, in terms of switching surge, when the second terminal of CB is shorting the circuit to the earth, answer the following questions: 1- Plot the equivalent electrical RLC circuit expressing the circuit case. 2- Explain the effect of R, L, and C values on the shape of generated oscillation. 3- Determine the relative attenuation occurring in three cycles in the overvoltage surge set up on a 75 kV cable fed through an air-blast circuit breaker when the breaker opens on a system short circuit. The network parameters are as follows: R= 8.5 0, L = 7.1mH, C= 0.0516 µF CB = Om VLC Restriking voltage (expanded time scale) R 21 Maximum Voltage V = 1.633 x Surge voltage v(t) = V[1 -e cos ont] Arc voltage Time System voltage CB open circuit Fault current Figure: 2
Expert Solution
steps

Step by step

Solved in 4 steps with 1 images

Blurred answer
Knowledge Booster
Coulomb's law
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,