A new bizarre coffee machine has two LED lights, RED and GREEN which light up based on certain inputs. You are asked to derive the internal circuit of the machine which enables the lights to glow. Depending on the inputs, both the lights, any one of the lights or none of the lights may glow. These two lights light up based on the following conditions: 1. Inputs (Conditions): A: Coffee beans. (A=1 if coffee beans are absent, A=0 otherwise) B: Water Temperature (B=1 if water temperature is suitable, B=0 otherwise) C: Milk (C=1 if milk is present, C=0 otherwise) D:Sugar (D= 1 if sugar is running low, D=0 otherwise) If the temperature is too hot/cold then the temperature is considered unsuitable. Outputs: R: RED LED G: GREEN LED 1. The RED LED will light up if there is adequate amount of milk and there is i) sufficient sugar or ii) no coffee beans left for use with a suitable water temperature 2. If there is no milk then the RED LED will still glow up if i) there are adequate coffee beans but no sugar. or ii) the water temperature is very cold. 3. The GREEN LED will light up if the water temperature is too high or when there is a scarcity of sugar in the machine with enough coffee beans present. Devise a truth table for the system above which will detect the presence of the diseases based on the given symptoms. In your truth table, the input columns should be in the order ABCD, where A is the MSB and D is the LSB. Draw K-map (s) based on the scenario above and derive simplified output (s).

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
A new bizarre coffee machine has two LED lights, RED and GREEN which light up based on certain inputs. You are asked to derive the internal circuit of the machine which enables the lights to glow. Depending on the inputs, both the lights, any one of the lights or none of the lights may glow. These two lights light up based on the following conditions: 1. Inputs (Conditions) : A: Coffee beans. (A=1 if coffee beans are absent, A=0 otherwise) B: Water Temperature (B=1 if water temperature is suitable, B=0 otherwise) C: Milk (C=1 if milk is present, C=0 otherwise) D :Sugar (D= 1 if sugar is running low, D=0 otherwise) If the temperature is too hot/cold then the temperature is considered unsuitable. Outputs: R : RED LED G : GREEN LED 1. The RED LED will light up if there is adequate amount of milk and there is i) sufficient sugar or ii) no coffee beans left for use with a suitable water temperature 2. If there is no milk then the RED LED will still glow up if i) there are adequate coffee beans but no sugar. or ii) the water temperature is very cold. 3. The GREEN LED will light up if the water temperature is too high or when there is a scarcity of sugar in the machine with enough coffee beans present. Devise a truth table for the system above which will detect the presence of the diseases based on the given symptoms. In your truth table, the input columns should be in the order ABCD, where A is the MSB and D is the LSB. Draw K-map (s) based on the scenario above and derive simplified output (s).
Question 2:
A new bizarre coffee machine has two LED lights, RED and GREEN which light up based on
certain inputs. You are asked to derive the internal circuit of the machine which enables the
lights to glow. Depending on the inputs, both the lights, any one of the lights or none of the lights
may glow.
These two lights light up based on the following conditions:
1. Inputs (Conditions) :
A: Coffee beans. (A=1 if coffee beans are absent, A=0 otherwise)
B: Water Temperature (B=1 if water temperature is suitable, B=0
otherwise)
C: Milk (C=1 if milk is present, C=0 otherwise)
D:Sugar (D= 1 if sugar is running low, D=0 otherwise)
If the temperature is too hot/cold then the temperature is
considered unsuitable
Outputs: R: RED LED
G: GREEN LED
1. The RED LED will light up if there is adequate amount of milk and there is
i) sufficient sugar
or
ii) no coffee beans left for use with a suitable water temperature
2. If there is no milk then the RED LED will still glow up if
i) there are adequate coffee beans but no sugar.
or
ii) the water temperature is very cold.
3. The GREEN LED will light up if the water temperature is too high or when
there is a scarcity of sugar in the machine with enough coffee beans
present.
Devise a truth table for the system above which will detect the presence of the diseases based
on the given symptoms. In your truth table, the input columns should be in the order
ABCD, where A is the MSB and D is the LSB.
Draw K-map (s) based on the scenario above and derive simplified output (s).
Transcribed Image Text:Question 2: A new bizarre coffee machine has two LED lights, RED and GREEN which light up based on certain inputs. You are asked to derive the internal circuit of the machine which enables the lights to glow. Depending on the inputs, both the lights, any one of the lights or none of the lights may glow. These two lights light up based on the following conditions: 1. Inputs (Conditions) : A: Coffee beans. (A=1 if coffee beans are absent, A=0 otherwise) B: Water Temperature (B=1 if water temperature is suitable, B=0 otherwise) C: Milk (C=1 if milk is present, C=0 otherwise) D:Sugar (D= 1 if sugar is running low, D=0 otherwise) If the temperature is too hot/cold then the temperature is considered unsuitable Outputs: R: RED LED G: GREEN LED 1. The RED LED will light up if there is adequate amount of milk and there is i) sufficient sugar or ii) no coffee beans left for use with a suitable water temperature 2. If there is no milk then the RED LED will still glow up if i) there are adequate coffee beans but no sugar. or ii) the water temperature is very cold. 3. The GREEN LED will light up if the water temperature is too high or when there is a scarcity of sugar in the machine with enough coffee beans present. Devise a truth table for the system above which will detect the presence of the diseases based on the given symptoms. In your truth table, the input columns should be in the order ABCD, where A is the MSB and D is the LSB. Draw K-map (s) based on the scenario above and derive simplified output (s).
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Wheatstone bridge method
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,