Make a standard calibration curve wherein the x-axis is the total concentration of standard 1 to 6 and the y axis is their corresponding corrected absorbance ..(Note never include the absorbance reading of the unknown sample when making a standard curve) Absorbance Reading Test Tube / Standard Glucose Concentration (mg/mL) Initial Absorbance Corrected Absorbance Blank 0.00 0.045 0.000 Standard 1 1.00 0.102 0.057 Standard 2 2.00 0.236 0.191 Standard 3 4.00 0.697 0.652 Standard 4 6.00 1.104 1.059 Standard 5 8.00 1.385 1.340 Standard 6 10.0 1.915 1.870 Unknown 2.42 0.361 0.316   Data Set for Quantitative Analysis    Tube No. ABSORBANCE TRIAL 1 TRIAL 2 TRIAL 3 TRIAL 4 TRIAL 5 TRIAL 6 1 0.041 0.044 0.046 0.046 0.046 0.046 2 0.102 0.103 0.103 0.102 0.102 0.102 3 0.236 0.235 0.240 0.235 0.237 0.235 4 0.703 0.698 0.696 0.694 0.693 0.695 5 1.102 1.100 1.11 1.101 1.103 1.07 6 1.39 1.386 1.384 1.383 1.38 1.385 7 1.915 1.920 1.917 1.913 1.912 1.911 8 0.355 0.356 0.357 0.360 0.358 0.377

Introduction to General, Organic and Biochemistry
11th Edition
ISBN:9781285869759
Author:Frederick A. Bettelheim, William H. Brown, Mary K. Campbell, Shawn O. Farrell, Omar Torres
Publisher:Frederick A. Bettelheim, William H. Brown, Mary K. Campbell, Shawn O. Farrell, Omar Torres
Chapter6: Solutions And Colloids
Section: Chapter Questions
Problem 6.23P: 6-23 We dissolved 0.32 g of aspartic acid in 115.0 mL of water and obtained a clear solution. After...
icon
Related questions
Question

Make a standard calibration curve wherein the x-axis is the total concentration of standard 1 to 6 and the y axis is their corresponding corrected absorbance ..(Note never include the absorbance reading of the unknown sample when making a standard curve)

Absorbance Reading

Test Tube / Standard

Glucose Concentration (mg/mL)

Initial Absorbance

Corrected Absorbance

Blank

0.00

0.045

0.000

Standard 1

1.00

0.102

0.057

Standard 2

2.00

0.236

0.191

Standard 3

4.00

0.697

0.652

Standard 4

6.00

1.104

1.059

Standard 5

8.00

1.385

1.340

Standard 6

10.0

1.915

1.870

Unknown

2.42

0.361

0.316

 

Data Set for Quantitative Analysis 

 

Tube No.

ABSORBANCE

TRIAL 1

TRIAL 2

TRIAL 3

TRIAL 4

TRIAL 5

TRIAL 6

1

0.041

0.044

0.046

0.046

0.046

0.046

2

0.102

0.103

0.103

0.102

0.102

0.102

3

0.236

0.235

0.240

0.235

0.237

0.235

4

0.703

0.698

0.696

0.694

0.693

0.695

5

1.102

1.100

1.11

1.101

1.103

1.07

6

1.39

1.386

1.384

1.383

1.38

1.385

7

1.915

1.920

1.917

1.913

1.912

1.911

8

0.355

0.356

0.357

0.360

0.358

0.377

Example only!
Glucose Standard Curve
0,9
0,8
y=mx + b
R? =_
0,7
0,6
0,5
0,4
0,3
0,2
0,1
0,5
1,5
2
2,5
-0,1 0
[Glucose] (ug/mL)
Absorbance at 480 nm
Transcribed Image Text:Example only! Glucose Standard Curve 0,9 0,8 y=mx + b R? =_ 0,7 0,6 0,5 0,4 0,3 0,2 0,1 0,5 1,5 2 2,5 -0,1 0 [Glucose] (ug/mL) Absorbance at 480 nm
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
UV and Visible Spectroscopy
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introduction to General, Organic and Biochemistry
Introduction to General, Organic and Biochemistry
Chemistry
ISBN:
9781285869759
Author:
Frederick A. Bettelheim, William H. Brown, Mary K. Campbell, Shawn O. Farrell, Omar Torres
Publisher:
Cengage Learning